{"title":"220\/240 Volt Contactors","description":"","products":[{"product_id":"eaton-dilm40-xtce040d00b","title":"Eaton Moeller DILM40 Contactor","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eEaton Moeller DILM40\u003c\/b\u003e is a 3-pole IEC power contactor widely utilized in Canadian elevator systems, specifically for \u003cb data-path-to-node=\"1\" data-index-in-node=\"120\"\u003eHydraulic Pump Starters\u003c\/b\u003e and \u003cb data-path-to-node=\"1\" data-index-in-node=\"148\"\u003eTraction Hoist Motors\u003c\/b\u003e. As part of the Moeller \"xStart\" series, it is a \u003cb data-path-to-node=\"1\" data-index-in-node=\"219\"\u003eFrame 3\u003c\/b\u003e device, recognized for its twin-terminal design which allows for easier wiring of different cable cross-sections.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eFrame Size:\u003c\/b\u003e Frame 3 (55mm wide)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eCurrent Rating (AC-3):\u003c\/b\u003e \u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"23\"\u003e40A\u003c\/b\u003e (Approx. 25 HP at 460V \/ 30 HP at 575V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eCoil Voltage:\u003c\/b\u003e \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"14\"\u003e220V 50Hz \/ 240V 60Hz\u003c\/b\u003e (Common in older Canadian 240V control logic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eIntegrated Contacts:\u003c\/b\u003e \u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"21\"\u003eNone (0 NO \/ 0 NC)\u003c\/b\u003e — This is a base power unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eTerminal Type:\u003c\/b\u003e Screw terminals with \"Box\" clamps for secure high-amperage connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eAuxiliary Contact Options (DILM150-XHI)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eBecause the base DILM40 has no built-in logic contacts, you must add an auxiliary block to handle the elevator's safety and operational signals:\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eDILM150-XHI22:\u003c\/b\u003e \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"15\"\u003e2 NO + 2 NC.\u003c\/b\u003e The standard configuration for Canadian elevator controllers. Provides 1 NC for safety string monitoring, 1 NC for electrical interlocking, 1 NO for seal-in, and 1 NO for brake signaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eDILM150-XHI11:\u003c\/b\u003e \u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"15\"\u003e1 NO + 1 NC.\u003c\/b\u003e A compact option for basic run\/feedback logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eDILM1000-XHI11-SI:\u003c\/b\u003e \u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"19\"\u003e1 NO + 1 NC (Side-Mount).\u003c\/b\u003e Used in shallow cabinets or MRL applications to save depth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"8\"\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eThermal Overload Protection\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe DILM40 is typically paired with the \u003cb data-path-to-node=\"10\" data-index-in-node=\"40\"\u003eZB65\u003c\/b\u003e series of thermal overload relays, which plug directly into the bottom of the contactor:\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eZB65-40:\u003c\/b\u003e \u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"9\"\u003e24A to 40A\u003c\/b\u003e range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eZB65-57:\u003c\/b\u003e \u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"9\"\u003e40A to 57A\u003c\/b\u003e range (Often used if the motor FLA is exactly 40A to prevent nuisance tripping).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"12\"\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eField Maintenance \u0026amp; Canadian Code Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eVoltage Verification:\u003c\/b\u003e In many Canadian jurisdictions, 240V coils were standard in \"industrial-style\" controllers. Ensure the coil code matches your transformer output. If you apply 120V to this \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"194\"\u003e240V coil\u003c\/b\u003e, the contactor will \"chatter,\" causing the main power poles to arc and eventually weld.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eMirror Contact Safety:\u003c\/b\u003e Eaton Moeller auxiliary contacts are \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"60\"\u003emechanically linked (Mirror Contacts)\u003c\/b\u003e. Per Canadian B44 code, if a power pole welds, the NC auxiliary contact is guaranteed to stay open. This allows the CPU to detect the failure and prevent the car from moving.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eTwin-Terminal Design:\u003c\/b\u003e Frame 3 contactors feature two separate terminal chambers per pole. This is ideal for elevator controllers that use \"double-up\" wiring for high-current hydraulic pumps. Ensure both sides are torqued to \u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"224\"\u003e3.3 Nm\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eDust \u0026amp; Environmental Care:\u003c\/b\u003e Moeller contactors are robust, but in dusty machine rooms, the armature can become sluggish. If you hear a \"humming\" noise while the contactor is energized, the pole faces may need cleaning, or the coil may be nearing the end of its life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"15\"\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003ePart Number Clarification\u003c\/b\u003e\u003c\/h3\u003e\n\u003cblockquote data-path-to-node=\"17\"\u003e\n\u003cp data-path-to-node=\"17,0\"\u003e\u003cb data-path-to-node=\"17,0\" data-index-in-node=\"0\"\u003eImportant:\u003c\/b\u003e If your unit is labeled \u003cb data-path-to-node=\"17,0\" data-index-in-node=\"35\"\u003eDILM40-22\u003c\/b\u003e, it is a factory-assembled version that includes the \u003cb data-path-to-node=\"17,0\" data-index-in-node=\"98\"\u003e2 NO + 2 NC\u003c\/b\u003e block already attached. If it is labeled only \u003cb data-path-to-node=\"17,0\" data-index-in-node=\"156\"\u003eDILM40\u003c\/b\u003e, it is the \"naked\" version.\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48120295162008,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_d971d5c8-60ff-4f31-8eeb-891ac590cdaa.jpg?v=1771954320"},{"product_id":"mcg-mc1d9511-u7","title":"MCG MC1D9511 U7 Contactor","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eMCG (MCG Surge Protection \/ Industrial)\u003c\/b\u003e \u003cb data-path-to-node=\"1\" data-index-in-node=\"44\"\u003eMC1D9511 U7\u003c\/b\u003e is a 3-pole high-capacity IEC contactor. In the Canadian elevator industry, this unit is typically found in \u003cb data-path-to-node=\"1\" data-index-in-node=\"164\"\u003eMain Line Power\u003c\/b\u003e applications, high-duty \u003cb data-path-to-node=\"1\" data-index-in-node=\"204\"\u003eHydraulic Starters\u003c\/b\u003e, or as the primary \u003cb data-path-to-node=\"1\" data-index-in-node=\"242\"\u003eTraction Machine Contactor\u003c\/b\u003e for mid-rise applications.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe part number breakdown is specific: \u003cb data-path-to-node=\"2\" data-index-in-node=\"39\"\u003e\"95\"\u003c\/b\u003e indicates the amperage, \u003cb data-path-to-node=\"2\" data-index-in-node=\"68\"\u003e\"11\"\u003c\/b\u003e indicates the integrated auxiliary contacts, and \u003cb data-path-to-node=\"2\" data-index-in-node=\"122\"\u003e\"U7\"\u003c\/b\u003e is the coil voltage code.\u003c\/p\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eCurrent Rating (AC-3):\u003c\/b\u003e \u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"23\"\u003e95A\u003c\/b\u003e (Heavy-duty hoist\/pump capacity)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eCoil Voltage:\u003c\/b\u003e \u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"14\"\u003e240V AC (60Hz)\u003c\/b\u003e (Indicated by the \u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"47\"\u003eU7\u003c\/b\u003e suffix)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eIntegrated Contacts:\u003c\/b\u003e \u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"21\"\u003e1 NO + 1 NC\u003c\/b\u003e (1 Normally Open, 1 Normally Closed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eFrame Size:\u003c\/b\u003e Large Frame (approx. 75mm - 85mm wide)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003ePower Rating:\u003c\/b\u003e Approx. \u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"22\"\u003e45 kW\u003c\/b\u003e at 400V \/ \u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"38\"\u003e60 HP\u003c\/b\u003e at 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"5\"\u003e\n\u003ch3 data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eIntegrated Auxiliary Contacts\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eUnlike some modular units, the \"11\" in this part number means the base unit is already equipped with logic contacts:\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e1 NO:\u003c\/b\u003e Typically used for the \"Seal-in\" (holding) circuit or signaling the controller that the contactor has pulled in.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003e1 NC:\u003c\/b\u003e Often used for electrical interlocking (e.g., ensuring the Up contactor cannot pull in if the Down is active) or monitoring the \"at rest\" state for safety string verification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"9\"\u003e\n\u003ch3 data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eCompatible Auxiliary Expansion\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"11\"\u003eIf the elevator controller requires more than the base 1 NO + 1 NC for safety feedback or brake monitoring, standard top-mount blocks are used:\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eMC-DN11:\u003c\/b\u003e 1 NO + 1 NC (Front mount)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMC-DN22:\u003c\/b\u003e 2 NO + 2 NC (Standard for safety chain monitoring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eMC-DN40:\u003c\/b\u003e 4 NO (Auxiliary logic signaling)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003ch3 data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eThermal Overload Relays\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"15\"\u003eTo protect the hoist or pump motor, the following overloads typically pair with the 95A frame:\u003c\/p\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eMC-LRD3361:\u003c\/b\u003e 55.0A to 70.0A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003eMC-LRD3363:\u003c\/b\u003e 63.0A to 80.0A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eMC-LRD3365:\u003c\/b\u003e 80.0A to 93.0A (Standard match for a 95A contactor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"17\"\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eField Maintenance \u0026amp; Canadian Code Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eCoil Voltage (U7):\u003c\/b\u003e The \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"23\"\u003e240V AC\u003c\/b\u003e coil is less common in modern 120V logic controllers but is frequently found in older Canadian \"legacy\" or \"industrial-style\" elevator controllers where 240V was pulled across two legs of the transformer. \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"236\"\u003eDouble-check your coil voltage\u003c\/b\u003e before replacing; if you put 120V into a U7 coil, it will chatter and burn out; if you put 240V into a 120V coil, it will fail instantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eTorque Warning:\u003c\/b\u003e For a 95A load, the box terminals require significant torque (\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"78\"\u003eapprox. 6.0 Nm\u003c\/b\u003e). In the high-vibration environment of an elevator machine room, loose power leads on a 95A contactor will cause rapid terminal carbonization and potential fire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eInterlocking:\u003c\/b\u003e If used in a reversing or Star-Delta pair, use the \u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"65\"\u003eMC-D0995\u003c\/b\u003e mechanical interlock kit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,0\"\u003e\u003cb data-path-to-node=\"19,3,0\" data-index-in-node=\"0\"\u003eSafety Monitoring:\u003c\/b\u003e Per Canadian code, ensure the integrated NC contact is utilized in the controller’s \"contactor-state monitoring\" circuit to prevent the car from running if a pole has welded.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48128887259288,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_4bcc8ebe-d5c6-477f-93fe-fe3f4d22d712.jpg?v=1772135616"},{"product_id":"siemens-3rt2028-1ap60","title":"Siemens 3RT2028-1AP60","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSiemens 3RT2028-1AP60\u003c\/b\u003e is a 3-pole, \u003cb data-path-to-node=\"1\" data-index-in-node=\"39\"\u003eSize S0\u003c\/b\u003e power contactor from the SIRIUS modular system. It is designed for switching 3-phase motors and high-power industrial circuits.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eContactor Size:\u003c\/b\u003e S0 (45 mm width).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eMain Contacts:\u003c\/b\u003e 3 NO (Normally Open).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eAuxiliary Contacts:\u003c\/b\u003e 1 NO + 1 NC (Integrated).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCoil Voltage:\u003c\/b\u003e 220 V AC (50 Hz) \/ 240 V AC (60 Hz).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eCurrent Rating (AC-3):\u003c\/b\u003e 38 A at 400 V.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003ePower Rating (AC-3):\u003c\/b\u003e 18.5 kW (approx. 25 HP at 460 V).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,6,0\"\u003e\u003cb data-path-to-node=\"3,6,0\" data-index-in-node=\"0\"\u003eTerminals:\u003c\/b\u003e Screw-type connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMotor Control:\u003c\/b\u003e Typically used as a main line contactor or for heavy-duty brake\/motor control in industrial elevator controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eReliability:\u003c\/b\u003e Rated for a mechanical service life of up to \u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"58\"\u003e10 million switching cycles\u003c\/b\u003e, essential for high-traffic installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eSafety Integrated:\u003c\/b\u003e Features a \u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"30\"\u003efinger-safe IP20 design\u003c\/b\u003e, protecting maintenance personnel from accidental contact with live terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eResponse Time:\u003c\/b\u003e Provides rapid opening and closing of contacts to ensure precise motor starting and stopping sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eAuxiliary Switch Blocks:\u003c\/b\u003e Can be expanded with front-mounted or side-mounted contact blocks if additional signaling is required for the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eSurge Suppressors:\u003c\/b\u003e RC elements or varistors can be plugged into the front to protect sensitive electronic logic from coil back-EMF.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eMechanical Interlocks:\u003c\/b\u003e Used when pairing two contactors for reversing applications to prevent both from closing simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eEnvironmental Rating:\u003c\/b\u003e Optimized for operation between \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"54\"\u003e-25°C and +60°C\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eStandard Compliance:\u003c\/b\u003e Fully compliant with \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"42\"\u003eIEC 60947\u003c\/b\u003e, \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"53\"\u003eUL\u003c\/b\u003e, and \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"61\"\u003eCSA\u003c\/b\u003e standards, making it suitable for installations governed by \u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"125\"\u003eCSA B44 \/ ASME A17.1\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eDirect Replacement:\u003c\/b\u003e This is the current \"SIRIUS Innovation\" replacement for the older, obsolete \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"96\"\u003e3RT1034-1AP60\u003c\/b\u003e or \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"113\"\u003e3RT1035\u003c\/b\u003e series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eTerminal Torque:\u003c\/b\u003e Periodic inspection of screw terminal tightness is recommended, especially in high-vibration machine rooms, to prevent arcing or heat damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48750383792280,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_1add8d3c-dfc3-4628-9b29-a6a0ab886f41.jpg?v=1774294791"}],"url":"https:\/\/parts4rem.ca\/collections\/220-240-volt-contactors.oembed","provider":"Parts4REM","version":"1.0","type":"link"}