{"title":"ECI 1000","description":"","products":[{"product_id":"kup-14d15-24-vdc","title":"KUP-14D15-24 Relay","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eKUP-14D15-24\u003c\/b\u003e (manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"34\"\u003eTE Connectivity\u003c\/b\u003e) is a heavy-duty, general-purpose \"Ice Cube\" relay. It is one of the most common components in modern elevator controllers, offering a high-density switching solution. Because of its 3-pole configuration, it is the standard choice for complex interlocking logic where multiple independent circuits must be toggled simultaneously by a 24V DC signal.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e TE Connectivity \/ Potter \u0026amp; Brumfield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e KUP-14D15-24\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eNumber of Poles:\u003c\/b\u003e \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"17\"\u003e3-Pole (3PDT \/ 3 Form C)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCoil Voltage:\u003c\/b\u003e 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eContact Rating:\u003c\/b\u003e 10A @ 240V AC \/ 28V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eBase Type:\u003c\/b\u003e 11-Pin Square Plug-in (Blade terminals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,6,0\"\u003e\u003cb data-path-to-node=\"3,6,0\" data-index-in-node=\"0\"\u003eCoil Resistance:\u003c\/b\u003e Approximately \u003cb data-path-to-node=\"3,6,0\" data-index-in-node=\"31\"\u003e\u003cspan class=\"math-inline\" data-math=\"472 \\Omega\" data-index-in-node=\"31\"\u003e$472 \\Omega$\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003e3-Pole 3PDT Switching:\u003c\/b\u003e The \u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"27\"\u003etriple-pole\u003c\/b\u003e design allows the relay to control three isolated circuits. A typical elevator application uses Pole 1 for a 110V AC load (e.g., a brake pilot), Pole 2 for a 24V DC signal to the CPU, and Pole 3 for a redundant \"Safety Check\" or a position indicator lamp.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eLogic Interlocking:\u003c\/b\u003e Used in hardware-based \"X-OR\" or \"AND\" logic strings where the state of multiple relays must be verified before the controller allows the car to move.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eDoor Operator Interface:\u003c\/b\u003e Frequently serves as the primary \"Open,\" \"Close,\" or \"Nudging\" relay, switching multiple signal paths to the door drive simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eBrake and Run Confirmation:\u003c\/b\u003e Provides the multiple feedback paths required for the controller to \"cross-check\" that the brake has lifted and the run contactors have energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003e92-Series 11-Pin Socket:\u003c\/b\u003e The mandatory 11-pin square base (different from the 8-pin version used for 2-pole relays).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eHold-Down Spring:\u003c\/b\u003e A metal wire clip used to lock the relay into the socket, preventing it from vibrating loose on the car-top or in the machine room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eFlyback Diode:\u003c\/b\u003e Essential across the 24V DC coil (Terminals 2 \u0026amp; 10) to suppress inductive \"kick\" and protect the controller's transistor drivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eLED Indicator Module:\u003c\/b\u003e Optional plug-in modules for the socket to provide visual confirmation of coil energization during troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eB44 Safety Limitations:\u003c\/b\u003e Under \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"30\"\u003eCanadian Elevator Code (B44)\u003c\/b\u003e, this is \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"68\"\u003enot\u003c\/b\u003e a force-guided safety relay. It must \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"109\"\u003enot\u003c\/b\u003e be used for primary safety-critical monitoring (such as door interlock verification) where a welded contact could bypass a safety function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eContact Pitting:\u003c\/b\u003e Over millions of cycles, switching inductive loads (coils\/motors) causes carbon buildup on the silver-cadmium oxide contacts. If the relay \"clicks\" but one of the three circuits fails, check for high resistance across that specific pole's blades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eVisual Inspection:\u003c\/b\u003e The clear \"Ice Cube\" case allows for immediate visual verification of the 3-pole armature movement. Discoloration of the coil winding or the clear plastic indicates overheating, often due to high ambient temperatures in the controller cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eTerminal Integrity:\u003c\/b\u003e Ensure the 11-pin blade terminals are not bent. Poor contact at the socket level is a common cause of intermittent \"Inconsistency\" faults in controllers that monitor all three poles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":47566351401112,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_19448f1a-5937-4fc0-8360-710d117af8b3.jpg?v=1772734969"},{"product_id":"eci-1000-bearing-kit","title":"1000-3000 ECI-1000 bearing kit","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"54\"\u003eECI 1000-3000\u003c\/b\u003e is the heavy-duty bearing kit specifically for the larger \u003cb data-path-to-node=\"1\" data-index-in-node=\"126\"\u003eECI 1000 series\u003c\/b\u003e gearbox. Because the 1000 series is designed for heavier door loads and higher traffic, these bearings are physically larger and rated for higher torque than those found in the 895 kit.\u003c\/p\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e \u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"13\"\u003e1000-3000\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e ECI (Electronic Controls Inc.) \/ S.E.E.S.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e * \u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"15\"\u003eECI 1000\u003c\/b\u003e (Heavy Duty)\u003c\/p\u003e\n\u003cul data-path-to-node=\"2,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,1,0,0\"\u003e\u003cb data-path-to-node=\"2,2,1,0,0\" data-index-in-node=\"0\"\u003eECI 1100\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,1,1,0\"\u003e\u003cb data-path-to-node=\"2,2,1,1,0\" data-index-in-node=\"0\"\u003eECI 1500\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eKit Contents:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"2,3,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,1,0,0\"\u003e\u003cb data-path-to-node=\"2,3,1,0,0\" data-index-in-node=\"0\"\u003eLarge-diameter output shaft bearings\u003c\/b\u003e (designed to handle the leverage of longer drive arms).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,1,1,0\"\u003e\u003cb data-path-to-node=\"2,3,1,1,0\" data-index-in-node=\"0\"\u003eHeavy-duty input shaft bearings.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,1,2,0\"\u003e\u003cb data-path-to-node=\"2,3,1,2,0\" data-index-in-node=\"0\"\u003eHigh-pressure oil seals\u003c\/b\u003e (specific to the larger 1000-series housing).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,1,3,0\"\u003e\u003cb data-path-to-node=\"2,3,1,3,0\" data-index-in-node=\"0\"\u003eInternal shim\/washer kit\u003c\/b\u003e for proper gear alignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,4,0\"\u003e\u003cb data-path-to-node=\"2,4,0\" data-index-in-node=\"0\"\u003eKey Identification:\u003c\/b\u003e If the gearbox housing has the larger, more robust casting, it requires this \u003cb data-path-to-node=\"2,4,0\" data-index-in-node=\"97\"\u003e1000-3000\u003c\/b\u003e kit. Using the 895 kit in this application is not possible as the bearings will be too small for the bore.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48162399518872,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_83a1fb43-6a74-4d41-8c2e-42d66299225e.jpg?v=1771867634"},{"product_id":"eci-door-operator-hard-stop-yellow","title":"ECI 1000-3016 Stop Roller","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb\u003eECI Hard Stop \u003c\/b\u003eis the high-visibility \u003cb data-path-to-node=\"1\" data-index-in-node=\"40\"\u003eyellow\u003c\/b\u003e polyurethane bumper specifically designed for the \u003cb data-path-to-node=\"1\" data-index-in-node=\"97\"\u003eECI (Electronic Controls Inc.)\u003c\/b\u003e line of door operators. This component is the primary mechanical limit used to arrest the motion of the door linkage at the end of its travel.\u003c\/p\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e ECI (Electronic Controls Inc.) \/ S.E.E.S. (Southern Elevator \u0026amp; Electric Supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e High-durometer \u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"25\"\u003eyellow polyurethane\u003c\/b\u003e. This material is specifically chosen over standard rubber for its superior resistance to oil, grease, and permanent deformation under repeated high-impact cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eColor:\u003c\/b\u003e Yellow (Standard for ECI high-visibility safety components).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e * \u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"15\"\u003eECI 895 series components\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"2,3,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,1,0,0\"\u003e\u003cb data-path-to-node=\"2,3,1,0,0\" data-index-in-node=\"0\"\u003eECI 1000 Series\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,1,1,0\"\u003e\u003cb data-path-to-node=\"2,3,1,1,0\" data-index-in-node=\"0\"\u003eECI 1100 Series\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,1,2,0\"\u003e\u003cb data-path-to-node=\"2,3,1,2,0\" data-index-in-node=\"0\"\u003eECI 1500 Series\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,4,0\"\u003e\u003cb data-path-to-node=\"2,4,0\" data-index-in-node=\"0\"\u003eFunction:\u003c\/b\u003e Acts as a positive mechanical stop for the drive arm or trolley. It prevents the operator from over-traveling, which protects the motor, drive chain, and door headers from structural damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48162454372504,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_708b5353-22a7-453f-bd20-c7cdb0996532.jpg?v=1771884117"},{"product_id":"eci-1000-chain-kit","title":"ECI 1000 chain kit","description":"\u003cp data-path-to-node=\"1\"\u003eECI 1000 chain kit designed for use on \u003cb data-path-to-node=\"1\" data-index-in-node=\"39\"\u003eECI (Electronic Controls Inc.)\u003c\/b\u003e door operators. This comprehensive replacement kit is used to overhaul the drive system, ensuring the smooth mechanical transfer of power from the motor to the door drive arm.\u003c\/p\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e ECI (Electronic Controls Inc.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e ECI 1000 and ECI 1100 series door operators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eKit Components:\u003c\/b\u003e Typically includes the primary drive chain (standard length), master links, and relevant mounting hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eFunction:\u003c\/b\u003e Replaces worn or stretched chains that cause \"jerking\" or noisy door operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,4,0\"\u003e\u003cb data-path-to-node=\"2,4,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e Recommended for systems where the chain has developed excessive slack or visible wear on the links.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48162607464600,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_73c9a44c-a05a-4aa0-a28c-7e147cca110a.jpg?v=1771883896"},{"product_id":"eci-2500-3055","title":"ECI 2500-3055 Additional I\/O Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eECI 2500-3055\u003c\/b\u003e is an optical position-sensing board used in \u003cb data-path-to-node=\"1\" data-index-in-node=\"63\"\u003eElectronic Controls, Inc.\u003c\/b\u003e door operator systems. It is the \"twin\" or precursor to the 3056 model, typically utilized to monitor the rotation of the motor or drive shaft. In Canadian elevator maintenance, this assembly is essential for defining the \u003cb data-path-to-node=\"1\" data-index-in-node=\"311\"\u003eSlowdown\u003c\/b\u003e and \u003cb data-path-to-node=\"1\" data-index-in-node=\"324\"\u003eLimit\u003c\/b\u003e points for the door cycle, replacing the need for traditional mechanical \"micro-switches.\"\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e 2500-3055\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eDescription:\u003c\/b\u003e Optical Cam \/ Speed Sensor Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eSensor Type:\u003c\/b\u003e Dual Infrared (IR) Photo-interrupters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eLogic Voltage:\u003c\/b\u003e \u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"15\"\u003e24V DC\u003c\/b\u003e (Supplied by the door operator controller)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eOutput Type:\u003c\/b\u003e Sourcing\/Sinking pulses based on cam slot interruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e ECI-1000, ECI-1000U, and older VFE\/Mover operators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic (Feedback \u0026amp; Limits)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThis board translates the mechanical rotation of the operator into digital signals used by the drive's CPU:\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eDigital Limits:\u003c\/b\u003e It generates the \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"33\"\u003eDOL (Door Open Limit)\u003c\/b\u003e and \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"59\"\u003eDCL (Door Close Limit)\u003c\/b\u003e. Once the sensors detect the solid portion of the cam, the board signals the controller to kill high-speed power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eSlowdown Detection:\u003c\/b\u003e It identifies the transition from high-speed travel to \"creep speed,\" ensuring the door arrives at the bumpers gently.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eStall Protection:\u003c\/b\u003e If the motor is energized but the 2500-3055 does not detect pulses (meaning the cam isn't turning), the board allows the controller to trigger a \u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"163\"\u003eStall Fault\u003c\/b\u003e to protect the motor windings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"8\"\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe 2500-3055 operates as part of a modular feedback loop:\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMechanical Interface\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eSlotted Cam \/ Encoder Disc:\u003c\/b\u003e The physical disc that rotates through the sensors. Note that different cam profiles (number of slots) are used depending on whether the operator is a \"Long Stroke\" or \"Short Stroke\" design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eMounting Brackets:\u003c\/b\u003e Specifically designed to align the sensors perfectly over the center of the rotating cam.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eInterconnects\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eHarness Assembly:\u003c\/b\u003e Multi-pin connector that carries the 24V supply and returns the pulse signals to the \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"103\"\u003eECI-1000\u003c\/b\u003e main board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"15\"\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eField Maintenance \u0026amp; Canadian Code Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"0\"\u003eCleaning Requirements:\u003c\/b\u003e These boards are highly sensitive to \u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"60\"\u003eCarbon Dust\u003c\/b\u003e from the DC motor brushes. In Canadian machine-room-less (MRL) or tight hoistway applications, dust buildup on the IR sensors will cause \"Short-cycling\" or the doors to reverse unexpectedly. Clean only with dry air or an electronics-safe swab.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003e\u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"0\"\u003eB44 Compliance:\u003c\/b\u003e The \u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"20\"\u003eCSA B44\u003c\/b\u003e code requires precise control over door kinetic energy. If this board sends \"dirty\" signals (due to a loose cam or dusty sensor), the door speed may become erratic, potentially exceeding the \u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"219\"\u003e10 Joule\u003c\/b\u003e energy limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003e\u003cb data-path-to-node=\"17,2,0\" data-index-in-node=\"0\"\u003eAlignment Check:\u003c\/b\u003e If the door fails to find its \"Home\" position or doesn't slow down, verify the cam disc isn't wobbling. A wobbling disc will clip the edges of the 2500-3055 sensors, leading to intermittent signal loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003e\u003cb data-path-to-node=\"17,3,0\" data-index-in-node=\"0\"\u003eVoltage Testing:\u003c\/b\u003e You should measure a steady \u003cb data-path-to-node=\"17,3,0\" data-index-in-node=\"45\"\u003e24V DC\u003c\/b\u003e at the power pins. When manually turning the motor, the signal pins should toggle between roughly \u003cb data-path-to-node=\"17,3,0\" data-index-in-node=\"150\"\u003e0V and 24V\u003c\/b\u003e as the slots pass through the sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48172000379032,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_077038e1-b757-4c0b-8b6c-b80e0f94c0c9.jpg?v=1772053126"},{"product_id":"eci-1000-xxxx","title":"ECI-1000-3050-R Door Operator Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eECI-1000-3050-R\u003c\/b\u003e is a specialized revision of the \u003cb data-path-to-node=\"1\" data-index-in-node=\"53\"\u003eElectronic Controls, Inc.\u003c\/b\u003e 1000-series microprocessor-based door operator. In the Canadian elevator service industry, the \u003cb data-path-to-node=\"1\" data-index-in-node=\"174\"\u003e\"-R\"\u003c\/b\u003e typically signifies a \u003cb data-path-to-node=\"1\" data-index-in-node=\"201\"\u003eRelay-logic compatible\u003c\/b\u003e or \u003cb data-path-to-node=\"1\" data-index-in-node=\"227\"\u003eRevised\u003c\/b\u003e interface board, commonly found in \u003cb data-path-to-node=\"1\" data-index-in-node=\"270\"\u003eThyssenKrupp (TKE)\u003c\/b\u003e, \u003cb data-path-to-node=\"1\" data-index-in-node=\"290\"\u003eNorthern\u003c\/b\u003e, and \u003cb data-path-to-node=\"1\" data-index-in-node=\"304\"\u003eRichmond\u003c\/b\u003e elevator modernizations. It is a high-performance DC chopper drive designed to manage the velocity, torque, and braking profiles of a DC door motor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e ECI-1000-3050-R\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eInput Power:\u003c\/b\u003e \u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"13\"\u003e120V AC, 50\/60Hz\u003c\/b\u003e (Standard Canadian Supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eMotor Output:\u003c\/b\u003e \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"14\"\u003e0 to 90V DC\u003c\/b\u003e (PWM regulated for 1\/6 HP to 1\/2 HP DC motors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eInterface Logic:\u003c\/b\u003e Multi-voltage (24V DC to 120V AC\/DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eDrive Architecture:\u003c\/b\u003e 4-Quadrant PWM (Pulse Width Modulation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eMounting:\u003c\/b\u003e Standard stand-offs for car-top operator housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic (Motion Control)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe 3050-R board utilizes precise timing and current-sensing logic to replace legacy mechanical limit switches:\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eProfile Management:\u003c\/b\u003e Independent potentiometers control \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"55\"\u003eHigh Speed\u003c\/b\u003e, \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"67\"\u003eLow Speed (Creep)\u003c\/b\u003e, and \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"90\"\u003eAcceleration\/Deceleration\u003c\/b\u003e ramps for both the opening and closing cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eNudging (DO4):\u003c\/b\u003e In response to a nudging signal (per \u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"52\"\u003eCSA B44\u003c\/b\u003e), the board overrides standard torque settings to close the door at a reduced speed and force.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eObstruction Sensing:\u003c\/b\u003e The board continuously monitors motor current. If an obstruction is met, the current spike triggers a \"Stall\" or a \"Reversal\" pulse back to the main controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"8\"\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe ECI-1000-3050-R functions as the \"brain\" of a modular system:\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003ePosition Feedback\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eECI 2500-3056 Optical Board:\u003c\/b\u003e Uses an infrared sensor to track a slotted cam on the motor shaft, providing \"virtual\" limits (DOL\/DCL) to the 3050-R board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003e1000-6601 Transformer:\u003c\/b\u003e Provides the necessary isolated power for the board’s logic and motor drive stages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eInterconnect Components\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003ePower Resistor (10 Ohm \/ 50W):\u003c\/b\u003e Essential for dynamic braking. It dissipates the energy generated by the motor when the door is decelerating or being forced closed by the linkages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"15\"\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eField Maintenance \u0026amp; Canadian Code Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003e\u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"0\"\u003eB44 Closing Force (Section 2.13.4):\u003c\/b\u003e Per Canadian safety code, the force to prevent a door from closing must not exceed \u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"119\"\u003e135N (30 lbf)\u003c\/b\u003e. On the 3050-R, this is calibrated via the \u003cb data-path-to-node=\"17,0,0\" data-index-in-node=\"176\"\u003eCLF (Close Force)\u003c\/b\u003e potentiometer. Technicians must use a pressure gauge to verify this annually.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003e\u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"0\"\u003eKinetic Energy:\u003c\/b\u003e Total kinetic energy must be restricted to \u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"59\"\u003e10 Joules\u003c\/b\u003e during normal operation. If the door speed is too high at the start of the slowdown, adjust the \u003cb data-path-to-node=\"17,1,0\" data-index-in-node=\"165\"\u003eDEC (Deceleration)\u003c\/b\u003e pot to ensure a smooth transition to creep speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003e\u003cb data-path-to-node=\"17,2,0\" data-index-in-node=\"0\"\u003eEnvironmental Cleaning:\u003c\/b\u003e Since the board is car-top mounted, it often accumulates \u003cb data-path-to-node=\"17,2,0\" data-index-in-node=\"81\"\u003ecarbon dust\u003c\/b\u003e from the motor brushes. This dust is conductive; if not cleaned regularly, it can cause \"shorting\" between the high-voltage DC motor terminals and the low-voltage logic traces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003e\u003cb data-path-to-node=\"17,3,0\" data-index-in-node=\"0\"\u003eDynamic Braking:\u003c\/b\u003e If the door \"slams\" into the open or close bumpers despite low-speed settings, the external \u003cb data-path-to-node=\"17,3,0\" data-index-in-node=\"109\"\u003eDynamic Braking Resistor\u003c\/b\u003e is likely open-circuit. Without this resistor, the 3050-R cannot \"soak up\" the motor's momentum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48176471703704,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_b9a206c6-500b-473d-bb36-86531117761a.jpg?v=1772139200"},{"product_id":"untitled-jun12_13-03-48","title":"ECI-1000 Door Op Motor 1000-3006","description":"\u003cp data-path-to-node=\"4\"\u003eThis heavy-duty Permanent Magnet DC motor is manufactured by Nidec Drive Systems specifically for high-reliability industrial door operator configurations.\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Nidec Drive Systems (Imperial Electric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eModel Number:\u003c\/b\u003e 48B17D1195\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eHorsepower (HP):\u003c\/b\u003e 1\/3 HP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eVoltage:\u003c\/b\u003e 48 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eCurrent (Amps):\u003c\/b\u003e 6.5A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003eSpeed:\u003c\/b\u003e 1150 RPM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003eDuty Cycle:\u003c\/b\u003e INT (Intermittent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\"\u003eInsulation Class:\u003c\/b\u003e Class H\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\"\u003eEnclosure Type:\u003c\/b\u003e TENV (Totally Enclosed Non-Ventilated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,10,0\"\u003e\u003cb data-path-to-node=\"5,10,0\" data-index-in-node=\"0\"\u003eFrame \/ Shaft:\u003c\/b\u003e SP5\/8K (5\/8\" Output Shaft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49234135613592,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_253295b4-035c-4235-9e3b-89db4aac1d3d.jpg?v=1781298445"},{"product_id":"spirator-kone","title":"Spirators","description":"","brand":"R.A.M. Parts","offers":[{"title":"Smartorx","offer_id":49249086472344,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false},{"title":"A831","offer_id":49249086505112,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false},{"title":"Kone MS-124F","offer_id":49249086537880,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_34c22d78-c686-414a-a6f3-1372d1803c2a.jpg?v=1781542392"},{"product_id":"argo-ag1000-msp06-hv-board","title":"Argo AG1000-MSP06-HV Board (ECI-1000 Compatible)","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,0,0\"\u003e\u003cb data-path-to-node=\"1,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Argo (ECI Compatible Premium Replacement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,1,0\"\u003e\u003cb data-path-to-node=\"1,1,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e AG1000-MSP06-HV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,2,0\"\u003e\u003cb data-path-to-node=\"1,2,0\" data-index-in-node=\"0\"\u003eComponent Type:\u003c\/b\u003e High-Voltage Solid-State Door Operator Control Board Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,3,0\"\u003e\u003cb data-path-to-node=\"1,3,0\" data-index-in-node=\"0\"\u003eCompatibility Platform:\u003c\/b\u003e Drop-in electronic equivalent for Elevator Components Inc. (ECI) Model 1000, 1000+, and 1000N series door operators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,4,0\"\u003e\u003cb data-path-to-node=\"1,4,0\" data-index-in-node=\"0\"\u003eInterchangeable Form Factors:\u003c\/b\u003e Replaces OEM part numbers matching the standard high-voltage ECI 1000 master control chassis configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49331339919512,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_7355d158-1be3-4d4e-999f-a7d4e4e10c8c.jpg?v=1782407822"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/collections\/ECI_895_door_operator.png?v=1781546014","url":"https:\/\/parts4rem.ca\/collections\/eci-1000.oembed","provider":"Parts4REM","version":"1.0","type":"link"}