{"title":"MCE-HC\/MC xxx Boards","description":null,"products":[{"product_id":"hc-db-ui-ipc","title":"HC-DB-UI\/IPC (Hall Call Data Board - Universal Interface \/ IPC)","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eHC-DB-UI\/IPC\u003c\/b\u003e is a high-density serial interface board used in \u003cb data-path-to-node=\"1\" data-index-in-node=\"66\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e dispatching and hall call systems. It acts as the \"Universal Interface\" (UI) between the main controller's logic and the \u003cb data-path-to-node=\"1\" data-index-in-node=\"220\"\u003eIPC\u003c\/b\u003e (Inter-Processor Communication) bus. This board is typically found in the main controller cabinet or a centralized dispatching hub for high-rise groups.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e HC-DB-UI\/IPC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eBus Type:\u003c\/b\u003e IPC (Inter-Processor Communication) \/ RS-485 Serial\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eVoltage:\u003c\/b\u003e 5V DC (Logic) \/ 24V DC (I\/O)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eConnectivity:\u003c\/b\u003e High-density ribbon cable headers and serial port connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e Used primarily with \u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"35\"\u003eHMC-PHC\u003c\/b\u003e and \u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"47\"\u003eiControl\u003c\/b\u003e dispatching systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eData Hubbing:\u003c\/b\u003e Collects hall call data from multiple serial \"risers\" (strings of hall stations) and consolidates them into a single data stream for the main dispatcher CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eProtocol Translation:\u003c\/b\u003e Translates the discrete signaling from hall call interface boards into the IPC protocol used by the main processor to make \"assignment\" decisions (which car gets which call).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eSystem Synchronization:\u003c\/b\u003e Ensures all cars in a group see the same call registry. When a call is registered on one car's system, the HC-DB-UI\/IPC propagates that \"Lamp On\" signal to all other cars in the group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eHC-MAIN \/ HC-MPU:\u003c\/b\u003e The primary dispatcher processor boards that mount above or connect to the UI\/IPC board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eRibbon Cables:\u003c\/b\u003e Connects the UI\/IPC board to the \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"48\"\u003eHC-ACI\u003c\/b\u003e (AC Interface) or \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"73\"\u003eHC-DCI\u003c\/b\u003e (DC Interface) boards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eTermination Resistors:\u003c\/b\u003e Jumpers or plug-in resistors required at the end of the IPC bus string to prevent data corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eB44 Communication Reliability:\u003c\/b\u003e Per code, hall call registration must be reliable. If the UI\/IPC board fails, the entire group may lose hall call functionality, often defaulting the cars to \"Independent\" or \"Wild\" operation where they only respond to car calls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eLED Diagnostics:\u003c\/b\u003e The board features \"TX\/RX\" (Transmit\/Receive) LEDs. If these LEDs are not flickering rapidly, it indicates a lock-up in the serial communication or a power failure to the logic chip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eAddress Conflicts:\u003c\/b\u003e If replacing this board, ensure all dip-switches and jumpers match the original exactly. Incorrect IPC addressing will cause \"Communication Loss\" faults and can potentially crash the entire group dispatching network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eCable Integrity:\u003c\/b\u003e The high-density ribbon cables are sensitive to EMI. Ensure they are not draped over high-voltage contactors or transformers. If \"phantom\" calls appear across the whole group, check for a loose or unshielded ribbon cable connected to this board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48200197701784,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_fe71f524-bd0f-4fc7-b5a4-f57464ec266b.jpg?v=1772725774"},{"product_id":"hc-aci-f","title":"HC-ACI-F (Hall Call AC Interface - F)","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eHC-ACI-F\u003c\/b\u003e is a discrete interface board used in \u003cb data-path-to-node=\"1\" data-index-in-node=\"51\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e controllers (typically \u003cb data-path-to-node=\"1\" data-index-in-node=\"107\"\u003eHMC\u003c\/b\u003e or \u003cb data-path-to-node=\"1\" data-index-in-node=\"114\"\u003ePHC\u003c\/b\u003e series). It is designed to interface high-voltage AC hall call signals with the low-voltage DC logic of the controller. The \"F\" designation generally refers to the hardware revision or a specific fuse-protected configuration for the inputs.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e HC-ACI-F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eInput Voltage:\u003c\/b\u003e \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"15\"\u003e120V AC\u003c\/b\u003e (Standard for legacy hall button circuits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eLogic Output:\u003c\/b\u003e \u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"14\"\u003e+5V DC\u003c\/b\u003e or \u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"24\"\u003e+12V DC\u003c\/b\u003e (Opto-isolated signals sent to the dispatching board)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eProtection:\u003c\/b\u003e Per-input glass fuses or fusible resistors (indicated by the \"-F\" suffix)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eInput Count:\u003c\/b\u003e Typically handles \u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"31\"\u003e8 to 12\u003c\/b\u003e discrete hall call inputs per board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eSignal Conversion:\u003c\/b\u003e When a passenger presses a hall button (120V AC circuit), the HC-ACI-F detects the voltage and uses an opto-isolator to send a \"clean\" low-voltage signal to the main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eIsolation:\u003c\/b\u003e It provides an electrical barrier between the \"dirty\" high-voltage field wiring in the hoistway and the sensitive microprocessor on the \u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"147\"\u003eHC-MAIN\u003c\/b\u003e or dispatch board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eCall Registration:\u003c\/b\u003e Works in tandem with a registration power supply to light the hall call lamps once the controller accepts the signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eHC-MAIN \/ HC-MPU:\u003c\/b\u003e The main dispatching boards that receive the logic signals from the HC-ACI-F.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eRibbon Cables:\u003c\/b\u003e Multi-conductor cables that connect the HC-ACI-F to the motherboard or CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eReplacement Fuses:\u003c\/b\u003e Small-amperage fuses (often 1\/4 Amp) for each input line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eFuse Troubleshooting:\u003c\/b\u003e If a specific floor refuses to register a hall call, the first point of failure is often the individual fuse on the \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"138\"\u003eHC-ACI-F\u003c\/b\u003e. This happens if a hall button shorts to ground in the hoistway.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eOpto-Isolator Failure:\u003c\/b\u003e Over time, the internal LEDs in the opto-isolators can dim or fail. If the fuse is good and 120V is present at the terminal but the controller doesn't \"see\" the call, the board usually requires replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eB44 Visual Feedback:\u003c\/b\u003e If the HC-ACI-F fails to send the signal to the CPU, the hall lamp will not illuminate. Per code, the passenger must receive visual confirmation that the call is registered.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eTerminal Integrity:\u003c\/b\u003e Because this board handles 120V AC, ensure all terminal screws are tight. Vibration can cause arcing on the high-voltage side, which can carbon-trace the board and lead to \"phantom\" calls (calls that trigger themselves).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48200390344856,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_f4ff5307-019c-4449-bda2-0d1cec92c581.jpg?v=1772725496"},{"product_id":"untitled-may13_10-02","title":"MCE HC-CTL-T Control Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eHC-CTL-T\u003c\/b\u003e is the \u003cb data-path-to-node=\"1\" data-index-in-node=\"20\"\u003eMain Traction Control Board\u003c\/b\u003e manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"64\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e. Unlike the hydraulic version, the \u003cb data-path-to-node=\"1\" data-index-in-node=\"132\"\u003e-T\u003c\/b\u003e suffix designates this board for \u003cb data-path-to-node=\"1\" data-index-in-node=\"168\"\u003eTraction\u003c\/b\u003e systems, where it manages the complex timing and feedback loops required for cable-driven elevators.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e: Main Logic \/ Processor PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e: Motion Control Engineering (MCE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eSystem Compatibility\u003c\/b\u003e: Primarily used in \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"40\"\u003eMCE HMC-1000-T\u003c\/b\u003e and \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"59\"\u003eVFMC\u003c\/b\u003e (Variable Frequency Motion Control) traction systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eApplication\u003c\/b\u003e: Geared and gearless traction applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eI\/O Interface\u003c\/b\u003e: High-density connectors for interface with the drive, encoder feedback, and hoistway positioning systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMotion Profile Generation\u003c\/b\u003e: Calculates the S-curve acceleration and deceleration patterns specifically for traction motors to ensure smooth starts and stops without \"jerking.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eDrive Interface\u003c\/b\u003e: Communicates directly with the AC or DC drive to command speed and torque while monitoring the drive's \"Ready\" and \"Fault\" status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eEncoder Processing\u003c\/b\u003e: Processes high-speed pulses from the motor encoder to track car position and speed with millimeter precision, which is critical for floor leveling in traction systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eBrake Control Logic\u003c\/b\u003e: Manages the precise timing of the mechanical brake release and set sequences, ensuring the motor is producing enough torque to hold the load before the brake lifts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eEncoder Cables\u003c\/b\u003e: Shielded, low-capacitance cables required to transmit pulse data from the motor to the board without signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eCommunication Bridge\u003c\/b\u003e: May be paired with a serial interface board (like the SC-BASR) to distribute I\/O to the car and hall stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003ePluggable Terminal Blocks\u003c\/b\u003e: Standard MCE-style green or black removable connectors for field wiring and easy board replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance\u003c\/b\u003e: Replacement boards must match the original revision and software version to remain compliant with \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"124\"\u003eCSA B44\u003c\/b\u003e standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eRevision Matching\u003c\/b\u003e: In traction systems, the board revision is critical; using an incompatible revision can cause \"roll-back\" or unintended motion due to differences in how the drive interface is handled.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eDiagnostics\u003c\/b\u003e: Use the onboard 7-segment display or LED array to monitor for traction-specific faults, such as \"Encoder Loss\" or \"Drive Fault.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eESD Protection\u003c\/b\u003e: As with all MCE logic boards, the high-density microprocessors are extremely sensitive to static; always use grounded protection when handling the board during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49103012298904,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_798e0635-730d-4c94-a140-ac41714ff58f.jpg?v=1778708063"},{"product_id":"hc-rb4-vfac","title":"MCE HC-RB4-VFAC Relay Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eHC-RB4-VFAC\u003c\/b\u003e is a specialized \u003cb data-path-to-node=\"1\" data-index-in-node=\"33\"\u003eRelay Interface Circuit Board\u003c\/b\u003e manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"79\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e. It is a critical sub-assembly used in \u003cb data-path-to-node=\"1\" data-index-in-node=\"151\"\u003eHydro Main\u003c\/b\u003e elevator controllers to manage high-voltage signaling and relay logic switching.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eComponent Type:\u003c\/b\u003e Relay Interface \/ Control PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003ePrimary Voltage:\u003c\/b\u003e \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"17\"\u003e120 V AC\u003c\/b\u003e (indicated by the \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"44\"\u003eVFAC\u003c\/b\u003e suffix).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eBoard Revision:\u003c\/b\u003e Common versions include Rev 4-1, 4-2, and 4-4.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eHardware:\u003c\/b\u003e Features multiple on-board relays (including a dedicated \u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"67\"\u003eH Relay\u003c\/b\u003e) used for logic routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eRelay Logic Interface:\u003c\/b\u003e Acts as the physical mounting and wiring interface for multiple control relays, centralizing the switching logic for the elevator's main hydraulic controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eCommunication \u0026amp; Control:\u003c\/b\u003e Provides the necessary communication pathways between the main CPU and the physical hardware (valves, contactors, or locks).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eHigh-Voltage Signal Distribution:\u003c\/b\u003e The \u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"38\"\u003eVFAC\u003c\/b\u003e designation confirms this board is designed to handle 120V AC signal levels, routing them to various field devices without requiring external intermediate terminal strips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eSystem Reliability:\u003c\/b\u003e By consolidating relays onto a single PCB, it reduces the amount of point-to-point wiring in the controller, minimizing potential failure points from loose wire nuts or crimps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eReplacement Relays:\u003c\/b\u003e The board utilizes standard plug-in or soldered relays; specifically, the \u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"94\"\u003eH Relay\u003c\/b\u003e is a common point of failure and replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eStandoff Mounting Kits:\u003c\/b\u003e Used to isolate the PCB from the metal controller cabinet to prevent grounding shorts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance:\u003c\/b\u003e As a core control component, ensure the board revision (e.g., Rev 4-4) matches the original precisely to maintain the elevator's safety listing and operational parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eVisual Inspection:\u003c\/b\u003e Regularly check the PCB for signs of overheating or \"burning\" around the relay pin solder joints, which can occur due to high-current switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eRelay Seating:\u003c\/b\u003e Ensure all plug-in relays are fully seated in their sockets; vibration from the hydraulic pump can occasionally cause them to loosen, leading to intermittent \"Out of Service\" faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eVoltage Testing:\u003c\/b\u003e When troubleshooting, verify that 120V AC is present at the input terminals. If the board is receiving power but not triggering relays, the internal trace or the relay coil itself has likely failed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49103156150424,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_ac95c5ea-7599-4b9a-8380-cf1d4affc3fb.jpg?v=1778707455"},{"product_id":"mce-hc-ipls-tr-t","title":"MCE HC-IPLS-TR-T","description":"\u003cul data-path-to-node=\"1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,0,0\"\u003e\u003cb data-path-to-node=\"1,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,1,0\"\u003e\u003cb data-path-to-node=\"1,1,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e HC-IPLS-TR-T\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,2,0\"\u003e\u003cb data-path-to-node=\"1,2,0\" data-index-in-node=\"0\"\u003eComponent Type:\u003c\/b\u003e Intelligent Positioning Landing System (IPLS) Interface Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,3,0\"\u003e\u003cb data-path-to-node=\"1,3,0\" data-index-in-node=\"0\"\u003eCompatibility Platform:\u003c\/b\u003e MCE Traction Controllers (configured with \"-T\" designation for traction application circuitry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,4,0\"\u003e\u003cb data-path-to-node=\"1,4,0\" data-index-in-node=\"0\"\u003eInput Interface:\u003c\/b\u003e Designed for standard digital landing system sensor arrays (including LS-QUTE steel tape and magnetic flag setups)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e The HC-IPLS-TR-T functions as the dedicated landing system reader and positional encoder interface board within MCE traction control networks. Mounted directly in the controller or car top terminal station, this board decodes high-speed real-time signals from the hoistway magnetic sensors or tape head reading units. It processes critical level indicators, including Door Zone (DZ), Up Leveling (UL), Down Leveling (DL), and floor substitution flags, transmitting clean binary positional logic straight to the main processor to determine perfect floor stopping boundaries.\u003c\/p\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49336011554968,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_3204f4c7-b01c-4ff6-83d8-c6efe67fcb1a.jpg?v=1782740145"},{"product_id":"mce-hc-uio-2","title":"MCE HC-UIO-2","description":"\u003ch3 data-path-to-node=\"0\"\u003eCore Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,0,0\"\u003e\u003cb data-path-to-node=\"1,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,1,0\"\u003e\u003cb data-path-to-node=\"1,1,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e HC-UIO-2 (also designated as HC-UIO-2-T)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,2,0\"\u003e\u003cb data-path-to-node=\"1,2,0\" data-index-in-node=\"0\"\u003eComponent Type:\u003c\/b\u003e Universal Input\/Output Expansion Printed Circuit Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,3,0\"\u003e\u003cb data-path-to-node=\"1,3,0\" data-index-in-node=\"0\"\u003eSystem Architecture:\u003c\/b\u003e Gen 2 \/ Motion Control Series (including IMC-AC, IMC-MG, and mGroup controllers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,4,0\"\u003e\u003cb data-path-to-node=\"1,4,0\" data-index-in-node=\"0\"\u003eMounting Type:\u003c\/b\u003e Panel-mounted controller chassis assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,5,0\"\u003e\u003cb data-path-to-node=\"1,5,0\" data-index-in-node=\"0\"\u003eWeight:\u003c\/b\u003e ~1.00 lb (0.45 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,6,0\"\u003e\u003cb data-path-to-node=\"1,6,0\" data-index-in-node=\"0\"\u003eOperating Voltage:\u003c\/b\u003e Standard low-voltage logic bus supplies powered directly from the main MCE backplane \/ power supply unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,7,0\"\u003e\u003cb data-path-to-node=\"1,7,0\" data-index-in-node=\"0\"\u003eI\/O Capacity:\u003c\/b\u003e Multi-channel configurable discrete inputs and outputs for call, signal, and monitoring functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eElevator Logic\u003c\/h3\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eMCE HC-UIO-2\u003c\/b\u003e serves as a core universal interface board within MCE controller networks. It acts as a configurable signal routing node that translates discrete field inputs—such as landing call buttons, car calls, position indicators, and key switches—into serial and parallel logic commands for the main processor.\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSignal Routing \u0026amp; Distribution:\u003c\/b\u003e Processes high-density field I\/O signals and passes them to the central controller CPU via internal ribbon\/serial communication links.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eConfigurable Input\/Output Pins:\u003c\/b\u003e Allows dynamic assignment of field functions depending on job-specific parameters programmed into the controller firmware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eStatus Indication:\u003c\/b\u003e Features onboard diagnostic LED arrays providing real-time visual feedback for active input states, output driving conditions, and board power rail health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eSystem Isolation:\u003c\/b\u003e Onboard optical isolation protects sensitive microprocessors from external field noise, voltage spikes, and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eAccessories\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eRibbon Cables:\u003c\/b\u003e Standard multi-pin MCE interconnect ribbon harnesses (for bus connection to adjacent processor or expander boards)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eCAN \/ Serial Cables:\u003c\/b\u003e C-RJ12 series communication cables (when interfacing across group or hub layouts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eMounting Hardware:\u003c\/b\u003e Standoffs, nylon guides, and chassis grounding hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eMating Terminal Blocks:\u003c\/b\u003e Heavy-duty pluggable terminal strip blocks for quick field wiring insertion and servicing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49546649993368,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_adb699d7-f0ef-45ef-b909-fb787febd5ea.jpg?v=1784842910"},{"product_id":"mce-hc-iox","title":"MCE HC-IOX","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_b9ccc7c3c0a8dce9-48\"\u003e\u003cb\u003ePart Number:\u003c\/b\u003e \u003cspan class=\"citation-81 citation-end-81\"\u003eHC-IOX (Input\/Output Expander Board)\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e MCE Heritage, IMC, and HMC series legacy traction\/hydraulic controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eI\/O Capability:\u003c\/b\u003e High-density auxiliary discrete input and output processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInterfacing:\u003c\/b\u003e Dual ribbon cable bus connections linking to the main processor, central backplane, or adjacent I\/O expansion racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eElevator Logic\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_b9ccc7c3c0a8dce9-49\"\u003e\u003cspan class=\"citation-80 citation-end-80\"\u003eServes as an expansion module to increase discrete field input and output capacity beyond the base controller motherboard limits.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReceives high-level call signals, auxiliary switch monitoring inputs, and system interlocks, converting field states into logic-level signals for the CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrives auxiliary field relays, status lamps, directional indicators, and call registered lights across multi-landing installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDual ribbon cable interconnect assemblies for system bus linking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePluggable screw-terminal header blocks for discrete field wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrinted circuit board card-cage guides and standoff mounting hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMaintenance \u0026amp; Code Details\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTroubleshooting:\u003c\/b\u003e Onboard diagnostic LEDs monitor field input and output activations. If an entire bank of I\/O drops out, check ribbon cable seat alignment, verify onboard bus power fuses, and inspect for field short circuits pulling down the logic power rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eReplacement Precautions:\u003c\/b\u003e Turn off system power prior to pulling ribbon cables or terminal blocks. Match any hardware address jumpers or matrix pin settings to the original board layout before restoration of power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49651092848792,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_589d781e-65aa-4aa5-b611-5ade862b244a.jpg?v=1786045018"},{"product_id":"mce-hc-i40","title":"MCE HC-I40","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_23de1cfeb00ffa4f-54\"\u003e\u003cb\u003ePart Number:\u003c\/b\u003e \u003cspan class=\"citation-95 citation-end-95\"\u003eHC-I40 (Input\/Output Expander Board)\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e MCE IMC-AC, IMC-MG, and HMC series legacy traction\/hydraulic elevator controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFunction:\u003c\/b\u003e Provides high-density discrete field input and output expansion capacity beyond base controller board limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_23de1cfeb00ffa4f-55\"\u003e\u003cb\u003eInterfacing:\u003c\/b\u003e \u003cspan class=\"citation-94 citation-end-94\"\u003eMulti-pin ribbon cable header bus links to the main processor board (MC-MP or MC-MP2) and backplane assemblies\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eElevator Logic\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eConverts discrete field signals (such as landing calls, car calls, position indicators, and auxiliary switches) into low-voltage logic signals for processor evaluation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReceives command signals from the main controller to energize field loads, including call-registered indicators, directional arrows, and floor status displays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExpands I\/O capacity to support higher floor counts, complex selective collective logic, or auxiliary signaling interfaces without overloading central bus processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInterconnect ribbon cable assemblies for system bus linking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePluggable terminal blocks for field call and signal wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandoff hardware and card-cage mounting tracks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMaintenance \u0026amp; Code Details\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTroubleshooting:\u003c\/b\u003e Onboard LEDs indicate real-time input and output activation states. If a sequence of calls or indicator lights fails, inspect ribbon cable seating, verify board power fuses, and check field lines for short circuits pulling down logic voltage rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eReplacement Precautions:\u003c\/b\u003e Disconnect system power before removing or inserting ribbon cables or terminal connectors to prevent board trace damage. Verify hardware configuration pins or jumpers match the failed board prior to powering up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49651104415896,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_36e08af6-48b5-4ff6-9319-7a8e71c861b9.jpg?v=1786045147"},{"product_id":"mce-hc-rdr-t","title":"MCE HC-RDR-T","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HC-RDR-T (Rear Door Board)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e MCE Motion 2000, Motion 4000, and HMC\/IMC series elevator controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFunction:\u003c\/b\u003e Dedicated door interface logic for controlling rear\/auxiliary car and hoistway door operators and door protective devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInterface:\u003c\/b\u003e Connects directly to the main processor bus and door safety circuit logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eElevator Logic\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eManages independent opening, closing, nudging, and door protection logic specifically for rear elevator entrances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEvaluates rear door zone signals, door open\/close limit switches, and rear safety edge\/curtain inputs before issuing run and gate switch commands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparates front and rear door operation logic to enable selective rear door opening based on floor call origin and landing configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-pin ribbon interconnect cables for main controller backplane connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePluggable screw-terminal headers for field wiring connections to the rear door operator and door protective devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePCB standoff hardware and card-cage mounting brackets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMaintenance \u0026amp; Code Details\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTroubleshooting:\u003c\/b\u003e Observe onboard diagnostic LEDs to verify rear door limit switch states (DOL, DCL) and door protective device inputs. If the rear doors fail to operate while front doors work normally, check the HC-RDR-T fuse, terminal connections, and rear door safety edge inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eReplacement Precautions:\u003c\/b\u003e Disconnect controller power prior to pulling terminal blocks or ribbon cables. Ensure any board configuration jumpers match the original board settings before applying power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49651138527384,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_f04d53a8-81a9-43a0-bf77-ac55ea7ef1a5.jpg?v=1786045263"},{"product_id":"mce-hc-oa","title":"MCE HC-OA","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HC-OA (HC-OA-120 Series Output Adapter \/ Output Array Board)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e MCE HMC, IMC, and Heritage series legacy controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eVoltage Rating:\u003c\/b\u003e 120VAC field output interface logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFunction:\u003c\/b\u003e Serves as a high-density solid-state or relay output adapter to interface logic-level CPU signals with 120VAC field loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eElevator Logic\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eReceives low-voltage discrete command signals from the main processor board and drives high-voltage (120VAC) external field components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControls field outputs such as call-registered indicator lamps, directional hall lanterns, position indicators, and auxiliary relay coils.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptically isolates low-voltage control electronics from high-voltage field wiring to protect system processors from voltage surges, back-EMF, and field ground faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-pin ribbon cable bus assemblies for main controller interconnects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePluggable screw-terminal header blocks for 120VAC output field wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCard-cage mounting tracks, standoffs, and replacement board fuses\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMaintenance \u0026amp; Code Details\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTroubleshooting:\u003c\/b\u003e Observe individual output channel LEDs to verify logic activation states. If an LED illuminates but the field device fails to energize, check the corresponding output fuse or field fuse, verify line voltage at the terminal, and check for open field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eReplacement Precautions:\u003c\/b\u003e Always remove power from the controller cabinet before pulling ribbon cables or terminal blocks. Ensure replacement board voltage ratings (e.g., HC-OA-120-12 \/ HC-OA-120-16) and board jumpers match the original unit prior to powering up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49651175030936,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_8f9dd77a-7a60-4c40-8a77-8f939b8d481d.jpg?v=1786045415"},{"product_id":"mce-mc-mp2","title":"MCE MC-MP2","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e MC-MP2 (Main Processor Board, Generation 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e MCE IMC-AC, IMC-MG, and HMC series legacy traction and hydraulic elevator controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eArchitecture:\u003c\/b\u003e Microprocessor-driven central control unit responsible for core dispatching, motion processing, and system safety monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInterface:\u003c\/b\u003e Multi-bus backplane interconnects, diagnostic keypad\/display port, and onboard communication channels for peripheral I\/O boards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eElevator Logic\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eServes as the primary system CPU, executing operational control software, velocity profile calculations, landing call allocations, and door sequencing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitors critical safety circuit inputs, door interlocks, limit switches, and fault signals to safely command drive run\/stop sequences and brake operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcesses diagnostic error codes, system parameters, and timer configurations while managing real-time data communication across auxiliary I\/O and drive interface boards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMain controller backplane interconnect card and ribbon bus assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostic computer\/handheld terminal interface cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem EPROM\/flash memory chips and battery backup module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCard-cage mounting tracks and retaining hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMaintenance \u0026amp; Code Details\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTroubleshooting:\u003c\/b\u003e Monitor the onboard alphanumeric diagnostic display and status LEDs (RUN, FAULT, COMM). A solid fault indicator or system lockup usually indicates corruption of parameter EEPROM data, low memory battery voltage, or an unhandled safety circuit trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eReplacement Precautions:\u003c\/b\u003e Disconnect all cabinet power before extracting the board. Ensure socketed firmware EPROMs and configuration DIP switch\/jumper settings are transferred directly from the original board to the replacement unit prior to power-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49651185418392,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_8256a506-454a-4026-be8f-f1973f03495a.jpg?v=1786045595"},{"product_id":"mce-mc-cgp-4","title":"MCE MC-CGP-4","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e MC-CGP-4 (Central Group Processor Board, Generation 4)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e MCE IMC, HMC, and legacy group controller supervisory systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eArchitecture:\u003c\/b\u003e Multi-car group dispatching processor dedicated to central coordination, call allocation, and traffic management across elevator banks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCommunication Interfacing:\u003c\/b\u003e Multi-channel serial bus and parallel ribbon interfaces to communicate directly with individual car controllers within the group\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eElevator Logic\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOperates as the master group dispatcher, evaluating landing hall call requests, car positions, direction of travel, and door states across all assigned group elevators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRuns traffic management algorithms to calculate ETA (Estimated Time of Arrival) for every car and dynamically assigns hall calls for optimal energy efficiency and reduced wait times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControls group features including peak-traffic dispatching (Up-Peak, Down-Peak, Balanced), parking policies, emergency power sequencing, and fire recall operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRibbon cable bus assemblies and multi-node interconnect cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackup battery module for system memory retention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem software EPROM\/Flash chips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCard-cage mounting tracks and retaining hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMaintenance \u0026amp; Code Details\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTroubleshooting:\u003c\/b\u003e Observe status LEDs (POWER, COMM, FAULT, RUN). If hall calls fail to register across the entire bank or cars ignore group calls and operate strictly in local mode, inspect communication lines, verify group bus fuses, and check that system addressing settings have not defaulted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eReplacement Precautions:\u003c\/b\u003e Remove controller cabinet power before extracting or seating the board. Ensure socketed software EPROMs, parameter memory chips, and configuration DIP switches are matched precisely to the original board before restoring power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49651196592280,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_52fadba0-c139-42bc-9231-eedf97ecd568.jpg?v=1786045749"},{"product_id":"mce-hc-pci-o","title":"MCE HC-PCI\/O","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HC-PCI\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBoard Type:\u003c\/b\u003e Peripheral Control \/ Input-Output Expansion Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e Designed for integration with MCE Hydro Controller series (such as the HMC-1000 and IMC-1000 controller lineups).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFunctionality:\u003c\/b\u003e Provides discrete interface capability between the main elevator controller unit and external field devices, managing signal routing for call buttons, indicators, and safety circuit monitoring points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eForm Factor:\u003c\/b\u003e Compact printed circuit board (PCB) with multi-pin header connections and terminal interface points for simplified wiring integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElevator Logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSignal Processing:\u003c\/b\u003e Translates low-voltage logic signals from the central controller module into field-level inputs and outputs, ensuring accurate communication across landing and car operating panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eI\/O Routing:\u003c\/b\u003e Manages discrete input\/output mapping for hall calls, car calls, position indicators, and operational status feedback to the main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Reliability:\u003c\/b\u003e Utilizes onboard signal conditioning and opto-isolation to isolate sensitive microprocessors from electrical noise, spikes, or field wiring fluctuations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49665761902744,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_40baa26b-56a2-4e71-9499-bbeb48e31c1c.jpg?v=1786389226"},{"product_id":"mce-hc-rd","title":"MCE HC-RD","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HC-RD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBoard Type:\u003c\/b\u003e Relay Driver Board \/ Output Interface Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e Designed for MCE Hydro Controller series (including HMC-1000, IMC-1000, and related legacy hydraulic controller platforms).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFunctionality:\u003c\/b\u003e Drives high-current external relays, contactors, and field heavy-duty loads using low-level logic signals directly from the main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eForm Factor:\u003c\/b\u003e Modular printed circuit board (PCB) equipped with multi-pin header inputs and quick-connect\/terminal block output connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElevator Logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePower \u0026amp; Load Isolation:\u003c\/b\u003e Acts as an intermediate power switching layer, isolating sensitive microcontrollers from inductive voltage spikes and electrical noise generated by mechanical contactors and heavy relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eActuator Control:\u003c\/b\u003e Manages actuation signals for valve solenoids, direction contactors, door operator power circuits, and signal indicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eLogic Execution:\u003c\/b\u003e Accepts low-voltage DC logic inputs from the main CPU board and energizes individual onboard\/offboard relay channels to perform high-voltage switching safely and synchronously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49665813708952,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_56db5f12-fb2b-4e36-98f8-73f2ae9dd943.jpg?v=1786389374"},{"product_id":"mce-hc-dfq","title":"MCE HC-DFQ","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HC-DFQ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBoard Type:\u003c\/b\u003e Digital Frequency \/ Quadrature Landing System Interface Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e MCE Hydro Controller series (including HMC-1000) and IMC-1000 control systems equipped with the LS-QUIK landing system architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_c7899298c27dec65-21\"\u003e\u003cb\u003eFunctionality:\u003c\/b\u003e \u003cspan class=\"citation-11 citation-end-11\"\u003eProcesses optical sensor and quadrature feedback signals from car-position positioning devices to transmit high-precision floor leveling, slowdown, and positioning data to the main elevator processor.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eForm Factor:\u003c\/b\u003e Modular printed circuit board (PCB) featuring dedicated optical sensor LED indicators and terminal connections for landing system feedback lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElevator Logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQuadrature Signal Processing:\u003c\/b\u003e Decodes high-speed quadrature pulse streams generated by the shaft encoder\/follower wheel assembly to track accurate car position and velocity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_c7899298c27dec65-22\"\u003e\u003cb\u003eZone \u0026amp; Leveling Detection:\u003c\/b\u003e \u003cspan class=\"citation-10 citation-end-10\"\u003eProcesses 50VDC quadrature signals and Outer Leveling Markers (OLM), translating landing zone data into logic-level inputs for floor-stop accuracy and re-leveling operations.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSignal Conditioning:\u003c\/b\u003e Converts incoming 115VAC auxiliary landing signals and 50VDC position feedback signals into low-voltage DC logic inputs safe for central CPU processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEncoder \/ follower wheel interface harness cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-pin interconnect ribbon cables for controller backplane link.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal block connectors for 50VDC quadrature and 115VAC sensor field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePCB mounting standoffs and card cage rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49665819902104,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_e7bd543e-8b29-461c-b56e-13c3d123b47c.jpg?v=1786389468"},{"product_id":"mce-hc-ci-o","title":"MCE HC-CI\/O","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HC-CI\/O (Call Interface \/ Input-Output Board)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_37647151604c9612-27\"\u003e\u003cb\u003eBoard Type:\u003c\/b\u003e \u003cspan class=\"citation-25 citation-end-25\"\u003eCall Interface \/ I\/O Expansion Module (Surface Mount Technology variant)\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_37647151604c9612-28\"\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e \u003cspan class=\"citation-24 citation-end-24\"\u003eDesigned for integration with MCE Hydro Controller series and standard MCE elevator control architectures (such as HMC and IMC system lineups).\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFunctionality:\u003c\/b\u003e Manages, processes, and distributes car and hall call signals, bridging peripheral fixture inputs and outputs with the central controller network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eForm Factor:\u003c\/b\u003e Modular printed circuit board (PCB) equipped with multi-pin communication headers, data bus connectors, and terminal connection points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElevator Logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSignal Handling:\u003c\/b\u003e Decodes and transmits input signals originating from car operating panels (COP) and hall fixture stations, ensuring low-latency communication with the main processing unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCall Registration:\u003c\/b\u003e Manages discrete or serial call registration, illumination tracking, and acknowledgment feedback for car and landing calls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eNetwork Communication:\u003c\/b\u003e Acts as an extension node on the controller's communication loop, stabilizing data flow and maintaining synchronized polling between field stations and the main CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49665825996952,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_ffad99aa-8b02-470e-9d50-7ff524395601.jpg?v=1786389565"},{"product_id":"mce-hc-mpu","title":"MCE HC-MPU","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HC-MPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBoard Type:\u003c\/b\u003e Main Processing Unit \/ Main Central Processor Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e Designed specifically as the central CPU architecture for the MCE Hydro Controller series (including HMC-1000 and IMC-1000 controller lineups).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFunctionality:\u003c\/b\u003e Serves as the primary operational brain of the elevator control system, executing real-time system logic, motion control algorithms, and system safety monitoring routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eForm Factor:\u003c\/b\u003e Multi-layer printed circuit board (PCB) featuring embedded microprocessors, non-volatile system memory sockets, diagnostic displays, and peripheral bus connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElevator Logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCentral Processing \u0026amp; Dispatching:\u003c\/b\u003e Processes all system inputs, call registrations, dispatching algorithms, door operation routines, and safety string monitoring parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBus Master Communication:\u003c\/b\u003e Coordinates and controls high-speed data communications with expansion boards (including I\/O modules, call interface boards, and relay drivers) across the backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMotion \u0026amp; Safety State Machine:\u003c\/b\u003e Manages velocity profile generation, leveling transitions, direction selection, fault detection, and safety chain interlock validation in real time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEPROM \/ Firmware chip sets (pre-programmed for job-specific field parameters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eController backplane communication bus connectors and ribbon cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOnboard lithium battery or retention capacitor (for non-volatile diagnostic log storage).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePCB mounting standoffs and card cage rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49665829994648,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_d13c6650-46cb-4d36-a31d-59c4644b10c8.jpg?v=1786389652"},{"product_id":"mce-mc-rs","title":"MCE MC-RS","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e MC-RS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_0bb416a9c2099326-36\"\u003e\u003cb\u003eBoard Type:\u003c\/b\u003e \u003cspan class=\"citation-57 citation-end-57\"\u003eSerial Communication \/ Line Driver Board (RS-232 \/ RS-422 Interface)\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e MCE Hydro Controller series (including HMC-1000) and legacy IMC series controllers (such as IMC-1000 and IMC-SCR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_0bb416a9c2099326-37\"\u003e\u003cb\u003eFunctionality:\u003c\/b\u003e \u003cspan class=\"citation-56 citation-end-56\"\u003eProvides serial data interface and signal conversion to establish communication between the main elevator controller CPU and external peripherals (e.g., CRT terminals, hand-held diagnostics, PC monitors, or modems).\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_0bb416a9c2099326-38\"\u003e\u003cb\u003eForm Factor:\u003c\/b\u003e \u003cspan class=\"citation-55 citation-end-55\"\u003eCompact printed circuit board (PCB) with multi-pin header connections, DIP\/toggle configuration switches, and serial communication ports.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElevator Logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSerial Signal Protocol Conversion:\u003c\/b\u003e Translates internal microcontroller TTL-level communications into RS-232 or RS-422 standard serial signals for external diagnostics and monitoring devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePeripheral Bus Interface:\u003c\/b\u003e Acts as a dedicated port driver to allow real-time parameter configuration, system diagnostic monitoring, and fault log retrieval without disrupting main processor execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eLine Isolation \u0026amp; Noise Immunity:\u003c\/b\u003e Buffers communication lines to protect central processor logic circuits from field electrical interference and ground loop spikes over long cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49665929019544,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_1c6d67ce-fe2b-46aa-a25f-0315f761ed4c.jpg?v=1786389930"},{"product_id":"mce-mc-pca","title":"MCE MC-PCA","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e MC-PCA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBoard Type:\u003c\/b\u003e Main Computer \/ Processor Control Architecture Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e Legacy MCE controller series (including HMC hydraulic, PHC hydraulic, and IMC traction platforms).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFunctionality:\u003c\/b\u003e Serves as the primary microprocessor control board, executing core system logic, coordinating data bus traffic, and directing overall controller operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eForm Factor:\u003c\/b\u003e Multi-layer printed circuit board (PCB) featuring system processor microcontrollers, socketed memory (EPROMs), card cage connectors, and multi-pin bus headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElevator Logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCentral Logic Execution:\u003c\/b\u003e Manages real-time processing for motion sequencing, floor dispatching, door operator commands, and direction control algorithms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInter-Board Communication:\u003c\/b\u003e Coordinates data transfer across peripheral interface boards (such as I\/O, call interface, and relay driver modules) to maintain system synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCar Communication Control (CCC):\u003c\/b\u003e Handles communications between paired controllers in duplex configurations as well as data links to diagnostic equipment and monitoring terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEPROM \/ Firmware chip sets (programmed with job-specific operational parameters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePCB card guide rails and backplane interconnect connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOnboard battery \/ capacitor back-up components for system parameter retention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49665944387736,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_4b446b63-584f-42ad-989b-997bc331cf64.jpg?v=1786390034"},{"product_id":"mce-mc-pa","title":"MCE MC-PA","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e MC-PA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBoard Type:\u003c\/b\u003e Processor Architecture \/ Main CPU Motherboard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e Legacy MCE controller series (including HMC hydraulic, PHC hydraulic, and IMC traction controller platforms).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFunctionality:\u003c\/b\u003e Acts as the central processing engine for the controller rack, executing core operational software, system timing routines, and high-level logic execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eForm Factor:\u003c\/b\u003e Multi-layer printed circuit board (PCB) with card-edge connectors, socketed microprocessors\/EPROMs, and system bus interface headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElevator Logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCentral Processing \u0026amp; Control:\u003c\/b\u003e Runs central algorithms for car movement, direction selection, floor positioning, and door operator timing profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Bus Master:\u003c\/b\u003e Manages communication backplane traffic between peripheral boards, including I\/O modules, signal expansion cards, and relay drivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSafety Monitoring \u0026amp; Diagnostics:\u003c\/b\u003e Continuously monitors system inputs and safety circuit integrity, generating fault logs and initiating safety stops if invalid operational states occur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEPROM \/ System firmware chip sets (pre-programmed with job-specific parameter files).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCard cage rails and backplane edge connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterconnect ribbon cables for peripheral expansion cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49665958969496,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_9c4ef51c-1e11-4d4e-bec1-90d54807d6f4.jpg?v=1786390111"},{"product_id":"mce-hc-pi","title":"MCE HC-PI","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HC-PI (also designated as HC-PI\/O)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBoard Type:\u003c\/b\u003e Position Indicator Interface \/ Signal Output Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e MCE Hydro Controller series (including HMC-1000 and IMC-1000 control system platforms).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFunctionality:\u003c\/b\u003e Drives and manages landing position indicator displays, hall lanterns, and direction arrows throughout the building and inside the elevator car.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eForm Factor:\u003c\/b\u003e Modular printed circuit board (PCB) equipped with multi-pin backplane headers and terminal interface connectors for display signal wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElevator Logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSignal Decoding:\u003c\/b\u003e Receives digital position and direction data from the main CPU motherboard and converts it into discrete output signals compatible with fixtures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDisplay Output Driver:\u003c\/b\u003e Powers discrete or multi-wire position indicator displays (including digital segments, single-line displays, and illuminated floor numbers).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDirection \u0026amp; Lantern Control:\u003c\/b\u003e Coordinates directional arrow illumination and chime\/hall lantern trigger signals to synchronize fixture status with car travel state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49665972830360,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_5b5bf148-e1b0-4207-a8c2-5fab30a5090a.jpg?v=1786390182"},{"product_id":"ls-hb-f","title":"LS-HB-F","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e LS-HB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE) \/ Nidec Elevator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComponent Type:\u003c\/b\u003e Landing Selector Heavy-Duty Limit Switch Base Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eContact Rating \/ Style:\u003c\/b\u003e Heavy-duty snap-action contact block with roller actuator mechanism\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e Designed for MCE landing selector columns, hoistway slowdown tracks, and terminal limit setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eElevator Logic\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePosition Tracking:\u003c\/b\u003e Triggered by hoistway selector cams to signal floor zone entry, slowdown initiation, and directional terminal limits back to the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSafety \u0026amp; Control Logic:\u003c\/b\u003e Provides positive physical position inputs to verify car travel speed and location, preventing over-travel into buffer zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eActuator Hardware:\u003c\/b\u003e Standard roller lever arm and return spring assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMounting Hardware:\u003c\/b\u003e Track mounting bolts, alignment washers, and terminal wiring hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMaintenance\/Code Details\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInstallation Notice:\u003c\/b\u003e Power off safety line before wiring. Ensure correct horizontal clearance to hoistway cams to prevent binding or excessive arm wipe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCode Compliance:\u003c\/b\u003e Installation must meet CSA B44 \/ ASME A17.1 elevator safety code standards for terminal stopping and selector devices. Requires functional safety testing by certified mechanics after replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49725129392280,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_986ff6e6-6865-4208-9bfe-e17e48739667.jpg?v=1787326601"},{"product_id":"mcr-hc-chp-t","title":"MCE HC-CHP-T","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HC-CHP-T\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComponent Type:\u003c\/b\u003e CAN Bus Hub \u0026amp; Auxiliary Controller Power Supply Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSeries \/ Controller Compatibility:\u003c\/b\u003e MCE HydroMotion, Motion 2000, Motion 4000, and iControl Controller Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCommunication Interface:\u003c\/b\u003e Multi-port CAN (Controller Area Network) bus distribution hub\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMounting Type:\u003c\/b\u003e Controller cabinet backplate \/ standoff card rack mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49780870152344,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_3b06148e-c1d2-4c01-a710-57a44e35ffca.jpg?v=1788295112"},{"product_id":"mce-tc-mpi-t","title":"MCE TC-MPI-T","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e TC-MPI-T\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComponent Type:\u003c\/b\u003e Cartop Motion Processor Interface \/ Selector Interface Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSeries \/ Controller Compatibility:\u003c\/b\u003e MCE Motion 4000 Traction Controller Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCommunication Interface:\u003c\/b\u003e High-speed CAN bus interface to main controller CPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMounting Type:\u003c\/b\u003e Cartop inspection box interior mount \/ PCB standoffs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49781079310488,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_252a8d77-eadf-449d-9a4b-465ca84524bb.jpg?v=1788295276"},{"product_id":"mce-hc-mpu-2","title":"MCE HC-MPU-2","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e HC-MPU-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComponent Type:\u003c\/b\u003e Main Processor Unit Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSystem Compatibility:\u003c\/b\u003e MCE Hydro-Centrum \/ HMC Series Hydraulic Elevator Controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInput Voltage:\u003c\/b\u003e 5V DC \/ 24V DC logic supply inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMounting Type:\u003c\/b\u003e Card cage \/ rack-mounted PCB chassis assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eElevator Logic\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePrimary Processor Functions:\u003c\/b\u003e Executes central controller operational logic, dispatching decisions, safety string verification, and call registration management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDiagnostics \u0026amp; Signals:\u003c\/b\u003e Features onboard diagnostic LED status indicators for real-time monitoring of system states, fault conditions, and communication bus traffic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFirmware Execution:\u003c\/b\u003e Drives elevator parameter configurations, door operator timing sequences, and floor positioning logic via board-level firmware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eEEPROM \/ Microcontroller Chips:\u003c\/b\u003e Socketted firmware ICs (sold separately or transferred from existing board).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInterfacing Hardware:\u003c\/b\u003e MCE Card Cage Guide Rails \u0026amp; Ribbon Cable Interconnect Sets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTerminal Blocks:\u003c\/b\u003e Direct-plug screw terminal headers for peripheral I\/O wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMaintenance\/Code Details\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eJurisdictional Code Compliance:\u003c\/b\u003e Designed to meet ASME A17.1 \/ CSA B44 Safety Code for Elevators and Escalators requirements when installed within original OEM control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eServiceability:\u003c\/b\u003e Recommended for direct visual inspection of onboard capacitors and solder trace integrity during routine preventative maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eReplacement Protocol:\u003c\/b\u003e Ensure total line-power and battery backup isolation prior to removal or insertion to prevent static damage to processing ICs. Verifying software version compatibility with existing job parameters prior to installation is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eReplaces HC-MPU\u003c\/p\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49912809193624,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_f966d5ea-2781-481f-a2e1-ab2c7c27d003.jpg?v=1789498258"}],"url":"https:\/\/parts4rem.ca\/collections\/mce-hc-xxx-boards.oembed?page=2","provider":"Parts4REM","version":"1.0","type":"link"}