{"title":"MCE-SC xxx Boards","description":null,"products":[{"product_id":"sc-base-d","title":"MCE SC-BASE-D (Circuit Board)","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSC-BASE-D\u003c\/b\u003e is a main logic motherboard used in \u003cb data-path-to-node=\"1\" data-index-in-node=\"50\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e legacy controllers (specifically the \u003cb data-path-to-node=\"1\" data-index-in-node=\"120\"\u003eVVMC\u003c\/b\u003e and \u003cb data-path-to-node=\"1\" data-index-in-node=\"129\"\u003eVFMC\u003c\/b\u003e series). It is the \"Dual\" or \"Drive\" variant of the SC-BASE backplane, often used in configurations involving two-car groups or specific drive interface requirements. It serves as the primary mounting surface for daughterboards and the landing area for safety and high-voltage logic.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e SC-BASE-D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eType:\u003c\/b\u003e Large-format Printed Circuit Board (PCB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eSupply Voltage:\u003c\/b\u003e 120V AC (Logic) \/ +\/- 15V DC \u0026amp; +5V DC (Bus Power)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eHardware:\u003c\/b\u003e Integrated terminal strips, ribbon headers, and manual toggle switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eSafety Circuit Consolidation:\u003c\/b\u003e Houses the terminal landings for the main safety string. It monitors the state of the governor, final limits, and emergency stop switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eRedundant Logic Paths:\u003c\/b\u003e The \"D\" (Dual) designation refers to its ability to handle cross-signals between two controllers or redundant safety monitoring paths required by specific drive profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003ePFLT (Phase Fault) Bypass:\u003c\/b\u003e Includes a physical toggle switch to bypass phase-fault sensing logic during hoistway setup or motor phasing tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eSignal Backplane:\u003c\/b\u003e Distributes logic signals to and from the \u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"60\"\u003eSC-SB\u003c\/b\u003e (Signal Board) daughterboards via fixed pin headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eSC-SB2K \/ SC-SB3K Boards:\u003c\/b\u003e Signal daughterboards that plug directly into the headers on the SC-BASE-D.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003ePilot Relays:\u003c\/b\u003e Typically clear-case, force-guided relays (like the MP or UP\/DN relays) soldered or clipped directly to the board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eRibbon Cables:\u003c\/b\u003e Connects the base board to the \u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"46\"\u003eHC-MAIN\u003c\/b\u003e or \u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"57\"\u003eCPU\u003c\/b\u003e board for higher-level dispatching logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eB44 Safety String Integrity:\u003c\/b\u003e This board handles the high-voltage safety loop. Because the terminal blocks are soldered to the PCB, vibration can lead to \"cold\" solder joints. If the safety string shows \"Open\" despite switches being closed, check the solder points on the back of the SC-BASE-D.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eRelay Lifecycle:\u003c\/b\u003e The pilot relays on this board are safety-critical (force-guided). If a relay contact pits or sticks, the entire board is usually replaced to maintain code compliance, as field-repairing safety-grade PCBs is restricted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eSwitch Position:\u003c\/b\u003e Per code, the \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"31\"\u003ePFLT Bypass\u003c\/b\u003e and any other logic bypass switches on this board must be in the \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"108\"\u003eOFF\/NORMAL\u003c\/b\u003e position for the car to be in public service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eVoltage Spikes:\u003c\/b\u003e Ensure the MOV (Metal Oxide Varistors) on the board are not scorched. These protect the logic from the inductive \"kick\" of the main contactors; if they fail, the logic chips on the daughterboards are often destroyed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48199985266840,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_ab2e3859-a683-424e-9065-ec710c9c55d6.jpg?v=1772725908"},{"product_id":"sc-base-t","title":"MCE SC-BASE-T Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSC-BASE-T\u003c\/b\u003e is a main logic and interface motherboard used in \u003cb data-path-to-node=\"1\" data-index-in-node=\"64\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e legacy controllers (specifically the \u003cb data-path-to-node=\"1\" data-index-in-node=\"134\"\u003eVVMC\u003c\/b\u003e and \u003cb data-path-to-node=\"1\" data-index-in-node=\"143\"\u003eVFMC\u003c\/b\u003e series). It acts as the central hub for signal distribution, safety circuit monitoring, and pilot relay control.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e SC-BASE-T\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eType:\u003c\/b\u003e Multi-layered Printed Circuit Board (PCB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eSupply Voltage:\u003c\/b\u003e 120V AC Logic Power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eLogic Voltage:\u003c\/b\u003e +5V DC, +\/-15V DC (regulated on-board or via ribbon)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eOn-Board Hardware:\u003c\/b\u003e Integrated toggle switches (PFLT Bypass), status LEDs, and high-pin-count ribbon cable headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eSafety String Monitoring:\u003c\/b\u003e Processes signals from the hoistway safety loop (terminals 17 through 20). It ensures that the Emergency Stop, Governor, and Final Limit switches are closed before allowing the car to run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003ePhase Fault Bypass:\u003c\/b\u003e Features a dedicated \u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"41\"\u003ePFLT\u003c\/b\u003e toggle switch that allows the technician to bypass phase-sensing logic for testing purposes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003ePilot Relay Control:\u003c\/b\u003e Manages the firing of the on-board pilot relays (typically small, clear-case relays) that provide the logic-level signal to the main contactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eBus Distribution:\u003c\/b\u003e Acts as a backplane that distributes power and data to daughterboards (like the SC-SB series) through fixed headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eSC-SB2K \/ SC-SB3K Daughterboards:\u003c\/b\u003e Secondary logic boards that plug directly into the headers on the SC-BASE-T.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eRibbon Cables:\u003c\/b\u003e Multi-conductor cables that link the SC-BASE-T to the Main CPU or Dispatching boards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eRelay Clips:\u003c\/b\u003e Plastic retainers used to hold the plug-in\/soldered pilot relays in place against vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eB44 Safety Compliance:\u003c\/b\u003e Uses mechanically linked (force-guided) relays for the safety circuit. If a pilot relay on the board sticks, the logic is designed to prevent the next run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eSolder Joint Inspection:\u003c\/b\u003e Terminal strips for the safety string (17, 18, 19, 20) are subject to high vibration. Inspect the underside of the PCB for \"cold\" or cracked solder joints if intermittent safety faults occur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eBypass Verification:\u003c\/b\u003e Per code, the \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"35\"\u003ePFLT Bypass\u003c\/b\u003e switch must be in the \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"69\"\u003eNORMAL\u003c\/b\u003e position for the car to be in service. Ensure this switch hasn't been left in the bypass position after a maintenance visit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eTerminal Torque:\u003c\/b\u003e Ensure the heavy-gauge field wires landed on the board's terminal strips are tight. Loose connections here can lead to localized heating and delamination of the PCB traces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48200442937496,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_10757a36-840f-469a-8dbf-dce8c290e117.jpg?v=1772725220"},{"product_id":"mce-sc-sb2k-t","title":"MCE SC-SB2K-T","description":"\u003cp data-path-to-node=\"1\"\u003eThis circuit board is the \u003cb data-path-to-node=\"1\" data-index-in-node=\"26\"\u003eMain Safety Board Traction\u003c\/b\u003e assembly manufactured by Motion Control Engineering (MCE). It is primarily used in VFMC-1000 Series M traction controllers.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003ePart Number\u003c\/b\u003e: SC-SB2K-T.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eRevision Level\u003c\/b\u003e: Common revisions include Rev 3 and Rev 4.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eCategory\u003c\/b\u003e: Relay I\/O \/ Main Safety Board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eApplication\u003c\/b\u003e: Traction elevator controllers (open and closed loop flux vector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e: Approximately 4.00 lbs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eSafety Circuit Monitoring\u003c\/b\u003e: Acts as the central interface for the elevator's safety string, including the emergency stop switch, governor, and car safety tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eTraction Control\u003c\/b\u003e: Specifically configured for traction units to monitor speed levels and acceleration\/deceleration rates in conjunction with drives like Torqmax or Yaskawa.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eTemporary Run Interface\u003c\/b\u003e: Includes terminal points (such as terminals 17, 18, and 36) used to jump the safety circuit for temporary run operations during installation or maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eFault Detection\u003c\/b\u003e: Monitors phase loss and emergency terminal limit switches to prevent unsafe car movement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003ePlug-in Relays\u003c\/b\u003e: The board typically utilizes a series of relays (often omitted if purchasing the board \"less relays\") for I\/O logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eJumper Kits\u003c\/b\u003e: Used for bypassing door operators, fire service, or emergency power during initial installation or troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eMounting Standoffs\u003c\/b\u003e: Nylon or metal standoffs for securing the PCB to the controller cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance\u003c\/b\u003e: This board is designed for compliance with \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"69\"\u003eASME A17.1 \/ CSA B44\u003c\/b\u003e (2000 and later codes) regarding safety circuit monitoring and emergency stop functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eTerminal Integrity\u003c\/b\u003e: Regularly inspect terminal 36, 36R, and 47 for secure connections, as these are critical for safety circuit bypass and door logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eDiscontinued Status\u003c\/b\u003e: Note that this specific board is discontinued by the manufacturer, necessitating the use of refurbished stock or certified repair services for maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eTesting Protocol\u003c\/b\u003e: Use the onboard terminal points to perform Governor and Car Safety Tests as required by annual and five-year safety inspections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48807236370584,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_6eaea840-38e2-4126-a0b7-8011245c4e41.jpg?v=1778784997"},{"product_id":"sc-baser-d","title":"MCE SC-BASER-D Interface Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSC-BASER-D\u003c\/b\u003e is a specialized high-speed serial interface and logic distribution board manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"105\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e. This board is specifically designed for the \u003cb data-path-to-node=\"1\" data-index-in-node=\"183\"\u003eMotion 4000\u003c\/b\u003e and \u003cb data-path-to-node=\"1\" data-index-in-node=\"199\"\u003eiControl\u003c\/b\u003e systems to facilitate communication between the main controller and auxiliary hardware.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e: Serial Network Interface \/ Logic PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e: Motion Control Engineering (MCE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eSystem Compatibility\u003c\/b\u003e: Motion 4000 and iControl Series controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCommunication Protocol\u003c\/b\u003e: High-speed Universal Serial Network (USN).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eI\/O Capacity\u003c\/b\u003e: Supports multiple auxiliary inputs and outputs via pluggable terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eDistributed Serial Hub\u003c\/b\u003e: Serves as a primary node on the Universal Serial Network, allowing the main processor to communicate with various car and hall stations through a simplified serial bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSignal Translation\u003c\/b\u003e: Acts as the interface point for auxiliary signals, routing high-voltage field inputs to the low-voltage logic processing of the main controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eEmergency Logic Interface\u003c\/b\u003e: Frequently used to manage inputs for Fire Phase I\/II, medical emergency operation, and earthquake sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eOn-board Diagnostic Monitoring\u003c\/b\u003e: Built-in circuitry allows the board to report its own status back to the main CPU for real-time fault monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eShielded Serial Cables\u003c\/b\u003e: High-quality twisted-pair cabling required to prevent electromagnetic interference on the data bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003ePluggable Terminal Blocks\u003c\/b\u003e: Removable screw-terminal connectors that allow for quick field replacement without individual rewiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eStandoff Mounting Kits\u003c\/b\u003e: Insulated mounting hardware used to secure the board within the control cabinet while preventing electrical shorts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance\u003c\/b\u003e: To maintain \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"38\"\u003eCSA B44.1\/ASME A17.5\u003c\/b\u003e equipment certification, replacement boards must match the original revision number exactly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eDiagnostic LEDs\u003c\/b\u003e: On-board indicators provide status for power, transmit (TX), and receive (RX); a steady \"Heartbeat\" LED confirms the board's internal processor is active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eTermination Jumper Settings\u003c\/b\u003e: The board must be correctly jumpered (using the \"Term\" jumper) if it is located at the physical end of the serial communication line to maintain bus impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eEnvironmental Requirements\u003c\/b\u003e: Rated for operation in machine rooms between 0°C and 40°C with protection against condensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49103098642584,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_b28ed87c-7d98-4df6-95eb-47acb49d9886.jpg?v=1778707645"},{"product_id":"sc-basr","title":"MCE SC-BASR Interface Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSC-BASR\u003c\/b\u003e is a high-speed serial interface and logic board manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"77\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e. It serves as a primary hub for distributed I\/O communication between the main processor and field devices within \u003cb data-path-to-node=\"1\" data-index-in-node=\"224\"\u003eMotion 4000\u003c\/b\u003e and legacy \u003cb data-path-to-node=\"1\" data-index-in-node=\"247\"\u003eVFMC\u003c\/b\u003e controller series.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e: Serial Network Interface \/ Logic PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e: Motion Control Engineering (MCE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eSystem Compatibility\u003c\/b\u003e: Motion 4000, iControl, and VFMC Series controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCommunication Protocol\u003c\/b\u003e: High-speed Universal Serial Network (USN).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eI\/O Capacity\u003c\/b\u003e: Supports multiple auxiliary inputs and outputs via pluggable terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eSerial Communication Hub\u003c\/b\u003e: Acts as a central node for the Universal Serial Network, allowing the main CPU to communicate with remote car and hall stations through a simplified wiring bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSafety \u0026amp; Fire Logic Interface\u003c\/b\u003e: Frequently routes critical auxiliary signals such as Fire Phase I\/II recall, earthquake operation inputs, and emergency power status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProgrammable Bypasses\u003c\/b\u003e: Features on-board dip switches or jumpers used to temporarily override specific faults during installation or maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eSignal Isolation\u003c\/b\u003e: Provides electrical isolation between high-voltage field signals and the low-voltage logic traces of the main controller processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eShielded Serial Cables\u003c\/b\u003e: Specific twisted-pair cabling required to maintain data integrity across the serial network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003ePluggable Terminal Blocks\u003c\/b\u003e: Removable screw-terminal connectors that allow for quick board replacement without rewiring individual field leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eStandoff Mounting Kits\u003c\/b\u003e: Insulated plastic or metal standoffs used to secure the board within the NEMA-rated controller cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance\u003c\/b\u003e: To maintain \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"38\"\u003eCSA B44.1\/ASME A17.5\u003c\/b\u003e equipment certification, replacement boards must match the original revision number exactly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eDiagnostic LEDs\u003c\/b\u003e: On-board indicators provide real-time status of power and data activity; a flickering \"Heartbeat\" LED typically indicates healthy communication with the main CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eTermination Jumper Settings\u003c\/b\u003e: The board must be correctly jumpered if it is at the end of the serial communication line to ensure proper bus impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eEnvironmental Requirements\u003c\/b\u003e: Rated for operation in machine rooms between 0°C and 40°C with protection against condensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49103107096728,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_b28ed87c-7d98-4df6-95eb-47acb49d9886.jpg?v=1778707645"},{"product_id":"sc-basr-t","title":"MCE SC-BASR-T Interface Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSC-BASR-T\u003c\/b\u003e is a high-speed serial interface and logic board manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"79\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e. It serves as a primary hub for distributed I\/O communication between the main processor and field devices within \u003cb data-path-to-node=\"1\" data-index-in-node=\"226\"\u003eMotion 4000\u003c\/b\u003e and legacy \u003cb data-path-to-node=\"1\" data-index-in-node=\"249\"\u003eVFMC\u003c\/b\u003e controller series.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e: Serial Network Interface \/ Logic PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e: Motion Control Engineering (MCE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eSystem Compatibility\u003c\/b\u003e: Motion 4000, iControl, and VFMC Series controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCommunication Protocol\u003c\/b\u003e: High-speed Universal Serial Network (USN).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eI\/O Capacity\u003c\/b\u003e: Supports multiple auxiliary inputs and outputs via pluggable terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eSerial Communication Hub\u003c\/b\u003e: Acts as a central node for the Universal Serial Network, allowing the main CPU to communicate with remote car and hall stations through a simplified wiring bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSafety \u0026amp; Fire Logic Interface\u003c\/b\u003e: Frequently routes critical auxiliary signals such as Fire Phase I\/II recall, earthquake operation inputs, and emergency power status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProgrammable Bypasses\u003c\/b\u003e: Features on-board dip switches or jumpers used to temporarily override specific faults during installation or maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eSignal Isolation\u003c\/b\u003e: Provides electrical isolation between high-voltage field signals and the low-voltage logic traces of the main controller processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eShielded Serial Cables\u003c\/b\u003e: Specific twisted-pair cabling required to maintain data integrity across the serial network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003ePluggable Terminal Blocks\u003c\/b\u003e: Removable screw-terminal connectors that allow for quick board replacement without rewiring individual field leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eStandoff Mounting Kits\u003c\/b\u003e: Insulated plastic or metal standoffs used to secure the board within the NEMA-rated controller cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance\u003c\/b\u003e: To maintain \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"38\"\u003eCSA B44.1\/ASME A17.5\u003c\/b\u003e equipment certification, replacement boards must match the original revision number exactly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eDiagnostic LEDs\u003c\/b\u003e: On-board indicators provide real-time status of power and data activity; a flickering \"Heartbeat\" LED typically indicates healthy communication with the main CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eTermination Jumper Settings\u003c\/b\u003e: The board must be correctly jumpered if it is at the end of the serial communication line to ensure proper bus impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eEnvironmental Requirements\u003c\/b\u003e: Rated for operation in machine rooms between \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"73\"\u003e0°C and 40°C\u003c\/b\u003e with protection against condensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49103116632216,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_b28ed87c-7d98-4df6-95eb-47acb49d9886.jpg?v=1778707645"},{"product_id":"sc-bahr-t","title":"MCE SC-BAHR-T Interface Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSC-BAHR-T\u003c\/b\u003e is a specialized circuit board manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"61\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e, typically used in older hydraulic elevator controllers. It serves as a \u003cb data-path-to-node=\"1\" data-index-in-node=\"166\"\u003eHigh-Voltage Interface Board\u003c\/b\u003e for brake or auxiliary hydraulic functions.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e: Interface \/ Logic PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e: Motion Control Engineering (MCE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eFunction\u003c\/b\u003e: High-voltage signal isolation and distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e: Often mounted on standoffs within the main controller cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eConnectivity\u003c\/b\u003e: Features multiple terminal strips for field wiring connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eSignal Translation\u003c\/b\u003e: Converts low-voltage logic signals from the main CPU into high-voltage outputs needed for hydraulic valves or brake solenoids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eHydraulic Brake Control\u003c\/b\u003e: The \u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"29\"\u003eBAHR\u003c\/b\u003e designation is often associated with Brake\/Auxiliary Hydraulic Relay functions, providing the final switching path for the brake lift circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eStatus Monitoring\u003c\/b\u003e: Provides feedback loops to the controller to confirm that physical relays or valves have successfully changed state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eSystem Protection\u003c\/b\u003e: Acts as a buffer to protect sensitive logic boards from electrical noise or voltage spikes generated by high-current inductive loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eReplacement Relays\u003c\/b\u003e: Often utilizes plug-in relays for critical switching functions, which are the most common field-replaceable parts on the board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eTerminal Jumpers\u003c\/b\u003e: Specific jumper settings (like \u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"49\"\u003ePFLT Bypass\u003c\/b\u003e) are used during installation or temporary operation modes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance\u003c\/b\u003e: Repairs or replacements must maintain the \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"68\"\u003eCSA B44\u003c\/b\u003e certification of the original controller; ensure the board revision (e.g., Rev 3.1 or 4.2) matches the job prints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eVisual Inspection\u003c\/b\u003e: Regularly check for darkened traces or \"hot spots\" around high-current terminal blocks, which can indicate loose connections or failing components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eTerminal Torque\u003c\/b\u003e: Periodically verify that all screw terminals are tight, as mechanical vibration from hydraulic pumps can loosen field wiring over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eVoltage Verification\u003c\/b\u003e: When troubleshooting, ensure the input signals from the CPU are reaching the board before assuming the PCB itself has failed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49103121350808,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_22b906fc-bdba-47e0-bd18-0448d2a37751.jpg?v=1778707509"},{"product_id":"sc-hce-2","title":"SC-HCE-2","description":"\u003cp data-path-to-node=\"0\"\u003eThe \u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eSC-HCE-2\u003c\/b\u003e is an electronic interface module manufactured by \u003cb data-path-to-node=\"0\" data-index-in-node=\"63\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e, typically used in their centralized network or group controller dispatch configurations (such as the iCentral series).\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eKey Technical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e SC-HCE-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eComponent Type:\u003c\/b\u003e Serial to Ethernet Communications Module \/ Hall Call Extension Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003ePrimary Function:\u003c\/b\u003e Acts as a network bridge converting serial communication data from localized elevator fixtures or hall call stations into standard Ethernet protocol for processing by the group dispatching system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,4,0\"\u003e\u003cb data-path-to-node=\"2,4,0\" data-index-in-node=\"0\"\u003eSystem Integration:\u003c\/b\u003e Found inside iCentral controller groups, localized serial fixture setups, and legacy MCE network interfaces to handle high-density call distribution and monitoring data transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49113483640984,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_c6df54d6-d4b0-4880-a071-2aecf576aa3d.jpg?v=1780092468"},{"product_id":"mce-sc-hdio","title":"MCE SC-HDIO","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eMCE SC-HDIO\u003c\/b\u003e is a printed circuit board assembly manufactured by Motion Control Engineering (MCE). It serves as a specialized, high-density input\/output interface card designed primarily for controllers updating legacy systems or complying with modern performance demands.\u003c\/p\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003ePart Type:\u003c\/b\u003e High Density Input \/ Output (I\/O) Control Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eCommon Revisions:\u003c\/b\u003e SC-HDIO Rev 2.0, Rev 2.1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eSystem Compatibility:\u003c\/b\u003e Extensively utilized across mid-to-high-spec MCE non-proprietary traction and hydraulic controller platforms (including early iControl architectures and updated variant series engineered around strict code compliance frameworks).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"4\"\u003eElevator Logic\u003c\/h2\u003e\n\u003cp data-path-to-node=\"5\"\u003eThis circuit board acts as a high-density matrix handling the dense flow of discrete signaling required between the main processor unit and peripheral field hardware.\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eSignal Densification:\u003c\/b\u003e Consolidates a vast array of low-voltage inputs and outputs onto a single board space, drastically reducing the physical space needed within the controller cabinet for field wiring terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eData Processing:\u003c\/b\u003e Interfaces directly with the main system bus to communicate real-time positional data, control signaling, and state changes back to the primary controller logic processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eMatrix Multiplexing:\u003c\/b\u003e Manages localized call registry handling, indicator lighting logic, and terminal signal processing cleanly without overloading peripheral relay logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"8\"\u003eAccessories\u003c\/h2\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe SC-HDIO relies on specific mechanical and electrical components within the controller cabinet layout for optimal field application:\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eTerminal Interface Blocks:\u003c\/b\u003e Utilizes multi-pin or screw-terminal strip configurations allowing field technicians to wire car calls, hall calls, and position indicators directly to individual ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eMCE System Interconnects:\u003c\/b\u003e Typically works in tandem with foundational control boards, such as the MCE SC-BASE assembly, to segregate auxiliary high-density I\/O handling from core safety string tracking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eRibbon \u0026amp; Bus Cabling:\u003c\/b\u003e Connects back to the main CPU motherboard using multi-conductor data ribbons or standard backplane arrangements to stream signal matrices with minimal latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"12\"\u003eMaintenance \/ Code Details\u003c\/h2\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eCode Compliance:\u003c\/b\u003e Designed to provide the additional physical I\/O infrastructure necessary to satisfy the complex signaling demands mandated by \u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"143\"\u003eASME A17.1 \/ CSA B44\u003c\/b\u003e (Canadian Elevator Code). This includes managing extra landing matrices required for independent fire service visual indicators, access key-switch parameters, and specialized directional indicator tracking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eField Troubleshooting:\u003c\/b\u003e Features onboard diagnostic light-emitting diodes (LEDs) positioned next to specific trace clusters. This allows maintenance technicians to visually confirm whether specific inputs (e.g., active calls or position switches) are sending or receiving power without breaking open connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eService \u0026amp; Component Longevity:\u003c\/b\u003e Relies entirely on highly durable solid-state circuitry. By shifting heavy call-routing and terminal logic onto a solid-state I\/O card, it eliminates physical point-wear, carbon build-up, and mechanical degradation common to legacy relay-driven selector setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49249792884888,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_b59e1ee9-482a-4c42-aff1-51466cf32935.jpg?v=1781560927"},{"product_id":"sc-hce-3","title":"SC HCE-2","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eMCE SC-HCE-2\u003c\/b\u003e (Serial Control \/ Hall Call Extension Ethernet Translation Assembly) is an advanced interface module engineered for high-performance communication translation within centralized elevator networks. It acts as the primary hardware gateway converting serial field data to Ethernet-based protocols for master controllers.\u003c\/p\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE) \/ Nidec\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e SC-HCE-2 (Supercedes older legacy SC-HCE-ME hardware variants)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eApplication Ecosystem:\u003c\/b\u003e Purpose-built for MCE iControl, iCue, and iCentral dispatching frameworks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eInterface Protocol:\u003c\/b\u003e Serial-to-Ethernet translation bridge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,4,0\"\u003e\u003cb data-path-to-node=\"2,4,0\" data-index-in-node=\"0\"\u003eForm Factor:\u003c\/b\u003e Compact, modular circuit card layout with dedicated mounting trace profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,5,0\"\u003e\u003cb data-path-to-node=\"2,5,0\" data-index-in-node=\"0\"\u003eDiagnostic Interface:\u003c\/b\u003e Built-in network activity LEDs and data transmission status indicators for real-time connection verification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49441726496920,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_826ed192-a46c-4625-b3ac-1f25196f0a66.jpg?v=1783717795"},{"product_id":"mce-scr-pri-ee-t","title":"MCE SCR-PRI-EE-T","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eMCE SCR-PRI-EE-T\u003c\/b\u003e is a high-performance elevator power relay interface circuit board engineered by Motion Control Engineering (MCE). Built to meet the rigid demands of modern commercial traction and SCR drive elevator control systems, this board functions as a critical communication and power logic interface.\u003c\/p\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e SCR-PRI-EE-T (Interchangeable\/Superseded by MCECSCR-PRI-EE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eAlternate Board Markings:\u003c\/b\u003e 1002-B0050 \/ 9000.1020\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eComponent Type:\u003c\/b\u003e SCR Power Relay Interface \/ Control Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,4,0\"\u003e\u003cb data-path-to-node=\"2,4,0\" data-index-in-node=\"0\"\u003eShipping Weight:\u003c\/b\u003e 2.0 lbs (approx. 0.91 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,5,0\"\u003e\u003cb data-path-to-node=\"2,5,0\" data-index-in-node=\"0\"\u003ePhysical Dimensions:\u003c\/b\u003e 20\" x 8\" x 3\" (approx. 50.8 cm x 20.3 cm x 7.6 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"3\"\u003eElevator Logic\u003c\/h2\u003e\n\u003cp data-path-to-node=\"4\"\u003eThis control board plays a vital role in processing high-level logic signals between the central elevator controller processing unit and the primary power relays\/SCR drive assemblies.\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSignal Routing:\u003c\/b\u003e Safely isolates and routes low-voltage logic commands to heavy-duty power relays, protecting delicate microprocessor infrastructure from high-current electrical noise and back-EMF.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eSystem Stability:\u003c\/b\u003e Ensures precise operational timing during the initiation of car movement, deceleration, and high-speed switching loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eTraction Compatibility:\u003c\/b\u003e Optimally configured to work within legacy and current-generation MCE control cabinets regulating power distribution to heavy commercial hoisting motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"6\"\u003eAccessories\u003c\/h2\u003e\n\u003cp data-path-to-node=\"7\"\u003eTo ensure a seamless drop-in installation or complete control cabinet overhaul, consider the following compatible system pairings:\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eMCE Relay PC Board Mounts:\u003c\/b\u003e Ideal for pairing with standard SCR-RI-T or IMC-RB relay auxiliary cards to expand system I\/O capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eReplacement Relays \u0026amp; Timers:\u003c\/b\u003e Heavy-duty plug-in relay modules matching original factory specifications to refresh worn contact points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eHeavy-Duty Wiring Harnesses:\u003c\/b\u003e High-insulation traveling cable connections and standard multi-pin terminal blocks to eliminate communication interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"10\"\u003eMaintenance \u0026amp; Code Details\u003c\/h2\u003e\n\u003cp data-path-to-node=\"11\"\u003eProper handling, diagnostic routines, and regulatory compliance are paramount for keeping lifting systems safe and operational.\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eDiagnostic Alignment:\u003c\/b\u003e When swapping out or servicing the power relay interface, technicians should inspect contact wear on secondary relays and perform standard system relearns (such as drive alignment or SPI tuning depending on adjacent drive modules) to establish clean signaling baselines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eHandling Precautions:\u003c\/b\u003e This interface board features static-sensitive components. Standard ESD (Electrostatic Discharge) guidelines must be followed during unboxing and terminal wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eRegulatory Compliance:\u003c\/b\u003e All component replacements and system integrations must conform completely to regional safety standards, adhering strictly to \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"149\"\u003eASME A17.1 \/ CSA B44 (Safety Code for Elevators and Escalators)\u003c\/b\u003e governing electrical safety circuits, control system design, and hardware performance thresholds within Canadian jurisdictions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49491313524888,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_0fda449b-2593-4589-acc0-d2fc9862d0f6.jpg?v=1784295720"}],"url":"https:\/\/parts4rem.ca\/collections\/mce-sc-xxx-boards.oembed","provider":"Parts4REM","version":"1.0","type":"link"}