{"title":"Other Relay Types","description":null,"products":[{"product_id":"omron-g5rl-1-e-power-relay4-pack","title":"Omron G5RL-1-E Power Relay(4 pack)","description":"\u003ch2 data-path-to-node=\"0\"\u003eCore Specifications\u003c\/h2\u003e\n\u003cul data-path-to-node=\"1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,0,0\"\u003e\u003cb data-path-to-node=\"1,0,0\" data-index-in-node=\"0\"\u003eBrand:\u003c\/b\u003e Omron\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,1,0\"\u003e\u003cb data-path-to-node=\"1,1,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e G5RL-1-E\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,2,0\"\u003e\u003cb data-path-to-node=\"1,2,0\" data-index-in-node=\"0\"\u003eComponent Type:\u003c\/b\u003e Low-Profile Power Relay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,3,0\"\u003e\u003cb data-path-to-node=\"1,3,0\" data-index-in-node=\"0\"\u003eCoil Voltage:\u003c\/b\u003e 115\/120 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,4,0\"\u003e\u003cb data-path-to-node=\"1,4,0\" data-index-in-node=\"0\"\u003eContact Rating:\u003c\/b\u003e 16 A @ 250 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,5,0\"\u003e\u003cb data-path-to-node=\"1,5,0\" data-index-in-node=\"0\"\u003eContact Arrangement:\u003c\/b\u003e SPDT (1 Form C) High-Capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003ekeyword ERB, RELY-0049 \u003c\/p\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49551707373720,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_a9b3a2ee-34ce-4ad4-83d6-0917d8ddca31.jpg?v=1785872085"},{"product_id":"schrack-v23050-a1110-a511-safety-relay-2-pack","title":"Schrack V23050-A1110-A551 Safety Relay (2 pack)","description":"","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49702348193944,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/A511_front.jpg?v=1786995077"},{"product_id":"schrack-v23050-a1110-a533-safety-relay-2-pack","title":"Schrack V23050-A1110-A533 Safety Relay (2 pack)","description":"\u003cp\u003eThe \u003cb\u003eSchrack V23050-A1110-A533\u003c\/b\u003e (part of the \u003cb\u003eSR6\u003c\/b\u003e series by TE Connectivity) is a high-performance \u003cb\u003eForce-Guided Safety Relay\u003c\/b\u003e. In the elevator industry, this relay is a critical \"Safety Integrity\" component, specifically designed so that the Normally Open (NO) and Normally Closed (NC) contacts are mechanically linked. This ensures that if one contact welds, the others cannot move, allowing the controller to detect a hardware failure.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Schrack (TE Connectivity)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e V23050-A1110-A533\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRelay Type:\u003c\/b\u003e Force-Guided \/ Linked Contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCoil Voltage:\u003c\/b\u003e 110V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eContact Configuration:\u003c\/b\u003e 6-Pole (3 NO \/ 3 NC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eContact Rating:\u003c\/b\u003e 8A @ 250V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCoil Resistance:\u003c\/b\u003e Approx. \u003cspan class=\"math-inline\"\u003e$10,080 \\Omega$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMounting:\u003c\/b\u003e PCB (Through-hole) or Socket-mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cb\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSafety Circuit Monitoring:\u003c\/b\u003e Used to monitor the state of the safety string (emergency stops, final limits, and pit switches) to provide a redundant signal to the microprocessor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRedundant Brake Control:\u003c\/b\u003e Frequently employed in the brake monitoring circuit. The 110V DC coil matches common brake voltages, while the force-guided contacts verify the brake has physically dropped before the next run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDoor Interlock Feedback:\u003c\/b\u003e Acts as the interface between high-voltage door contacts and low-voltage controller inputs, ensuring the car cannot move if a contact is welded in the \"made\" position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFault Detection:\u003c\/b\u003e If an NO contact welds shut, the NC contact is mechanically prevented from closing. The controller sees this \"mismatch\" and prevents the elevator from restarting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSR6 DIN-Rail Socket:\u003c\/b\u003e Allows the PCB-style relay to be mounted on a standard 35mm DIN rail for easier field replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRetaining Clip:\u003c\/b\u003e A metal or plastic spring clip used to secure the relay into a socket in high-vibration environments (like a car-top station).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRC Snubber \/ Varistor:\u003c\/b\u003e Used across the 110V DC coil to suppress the inductive \"kick\" when the relay de-energizes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMarking Tags:\u003c\/b\u003e Snap-on labels to identify the relay's specific function (e.g., \"SMR\" for Safety Monitor Relay).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cb\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCSA B44 Compliance:\u003c\/b\u003e Under \u003cb\u003eCanadian Elevator Code (B44)\u003c\/b\u003e, any single failure in a safety-related circuit must not allow the elevator to start or run. This relay is a primary tool for achieving \"single-failure-proof\" logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eContact Resistance Testing:\u003c\/b\u003e During troubleshooting, if the elevator is stuck on a \"Redundancy Fault,\" check the resistance of the NC contacts while the coil is de-energized. High resistance (above \u003cspan class=\"math-inline\"\u003e$0.5 \\Omega$\u003c\/span\u003e) indicates carbon buildup or pitting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCoil Failure:\u003c\/b\u003e 110V DC coils are susceptible to burning out if the DC power supply is poorly filtered or experiencing spikes. Verify the coil resistance; an \"Open\" reading requires immediate replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eReplacement Warning:\u003c\/b\u003e \u003cb\u003eNever\u003c\/b\u003e replace a V23050 force-guided relay with a standard 110V general-purpose relay. Standard relays lack the mechanical linkage required for safety monitoring and will void the B44 code compliance of the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49702353797272,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/a511_1.jpg?v=1786995248"},{"product_id":"potter-brumfield-rt314024f-power-relay-4-pack","title":"Potter \u0026 Brumfield RT314024F Power Relay (4 pack)","description":"\u003cp\u003eThe \u003cb\u003ePotter \u0026amp; Brumfield RT314024F\u003c\/b\u003e (a division of \u003cb\u003eTE Connectivity\u003c\/b\u003e) is a compact, high-capacity \"Miniature Power PCB Relay.\" In the elevator industry, this specific 24V DC relay is a standard component soldered onto controller mainboards, car-top interface cards, and door operator boards (such as those from GAL or ECI) to bridge low-power logic with high-power field devices.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e Potter \u0026amp; Brumfield (TE Connectivity)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePart Number:\u003c\/b\u003e RT314024F (Successor to the Schrack RT series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eNumber of Poles:\u003c\/b\u003e \u003cb\u003e1-Pole (SPDT \/ 1 Form C)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCoil Voltage:\u003c\/b\u003e 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eContact Rating:\u003c\/b\u003e 16A @ 250V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMounting:\u003c\/b\u003e PCB (Through-hole)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eContact Material:\u003c\/b\u003e Silver Nickel (AgNi 90\/10)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCoil Resistance:\u003c\/b\u003e \u003cspan class=\"math-inline\"\u003e$1,440 \\Omega$\u003c\/span\u003e (Nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cb\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eOutput Interface:\u003c\/b\u003e Acts as the primary switching point for the microprocessor to engage larger 110V or 24V contactors, such as the Main Run or Directional contactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDoor Operator Commands:\u003c\/b\u003e Integrated into door boards to execute \"Open,\" \"Close,\" and \"Nudging\" commands by switching the pilot voltage to the motor drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBrake Logic:\u003c\/b\u003e Often used in the brake-holding circuit to signal the brake power supply to drop to a lower \"holding\" voltage once the car is in motion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eEmergency Power (EFO):\u003c\/b\u003e Swings the signal to the \"Fire Service\" or \"Emergency Power\" indicator lamps on the COPs and hall stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cb\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRT78726 Socket:\u003c\/b\u003e A DIN-rail mountable socket that allows this PCB relay to be used as a plug-in component for easier field replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePlastic Retaining Clip:\u003c\/b\u003e A \"Relay-to-Socket\" lock that prevents the unit from vibrating loose, which is critical for car-top stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eLED\/Protection Module:\u003c\/b\u003e Plug-in modules for the socket that provide a visual \"Power On\" LED and a flyback diode to protect the 24V DC driver circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMarking Tags:\u003c\/b\u003e Snap-on white plastic labels used to identify the relay's specific software function (e.g., \"DO\" for Door Open).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cb\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eB44 Safety Limitations:\u003c\/b\u003e Under \u003cb\u003eCanadian Elevator Code (B44)\u003c\/b\u003e, this is \u003cb\u003enot\u003c\/b\u003e a force-guided safety relay. It must \u003cb\u003enever\u003c\/b\u003e be used as the primary monitoring device for safety-critical circuits (like the safety string or interlock verification) where a welded contact could bypass a safety function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eContact Pitting:\u003c\/b\u003e While rated for 16A, high-cycle door operations will eventually cause carbon buildup on the silver-nickel contacts. If the relay \"clicks\" but the door fails to move, check for high resistance (over \u003cspan class=\"math-inline\"\u003e$0.5 \\Omega$\u003c\/span\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eVoltage Transients:\u003c\/b\u003e Ensure the 24V DC supply is filtered. Voltage spikes can damage the fine wire in the \u003cspan class=\"math-inline\"\u003e$1,440 \\Omega$\u003c\/span\u003e coil, leading to an \"Open\" coil failure and a dead output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFlux-Proof (F):\u003c\/b\u003e The \"F\" suffix indicates the relay is flux-proof for soldering. However, it is not hermetically sealed. In hydraulic machine rooms, ensure the relay is protected from oil mist, which can contaminate the contacts over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49702363660440,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rt3_1.jpg?v=1786995448"},{"product_id":"omron-g5v-2-48vdc-relay-5-pack","title":"Omron G5V-2 48VDC Relay (5 pack)","description":"\u003cp\u003e\u003cspan class=\"citation-653\"\u003eThe \u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-653\"\u003eOmron G5V-2 48VDC\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-653 citation-end-653\"\u003e is a miniature, low-signal double-pole, double-throw (DPDT) relay.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e In the Canadian elevator industry, this relay is frequently found on printed circuit boards (PCBs) within controllers, signal fixtures, and door operator logic boards.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCoil Voltage:\u003c\/b\u003e 48V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-652\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-652\"\u003eContact Form:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-652 citation-end-652\"\u003e DPDT (2 Form C)\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eContact Rating:\u003c\/b\u003e 2 A at 30V DC \/ 0.5 A at 125V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMounting Type:\u003c\/b\u003e Through-hole PCB mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTerminal Pitch:\u003c\/b\u003e Standard DIP (Dual In-line Package) footprint\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eKey Information\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eApplication:\u003c\/b\u003e These relays are often used to interface low-power logic signals with higher-voltage components. In elevator systems, you will often find them on floor selector boards or within call-registration circuits that operate on 48V logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHigh Sensitivity:\u003c\/b\u003e\u003cspan class=\"citation-651 citation-end-651\"\u003e The G5V-2 series is known for high coil sensitivity, allowing it to be driven directly by many solid-state circuits without overloading the controller's output.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFully Sealed:\u003c\/b\u003e\u003cspan class=\"citation-650 citation-end-650\"\u003e The \"sealed\" construction protects the internal contacts from the dust and carbon common in elevator machine rooms and hoistways.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e This prevents contact oxidation, which is a frequent cause of intermittent signal failures in older 48V systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-649\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"citation-649\"\u003eGold-Plated Contacts:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-649 citation-end-649\"\u003e These relays typically feature crossbar bifurcated contacts with gold plating.\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e This design is ideal for \"dry circuits\" (low current\/low voltage) where maintaining low contact resistance is critical for signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCompact Footprint:\u003c\/b\u003e Its small size allows multiple relays to be packed onto a single control board, facilitating complex switching logic in a minimal amount of space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49762068168856,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/g5v-1.jpg?v=1787952190"},{"product_id":"dpc01dm69-3-phase-monitoring-relay","title":"DPC01DM69 3 Phase monitoring relay","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eManufacturer \/ Brand:\u003c\/b\u003e Carlo Gavazzi\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eOEM Part Number (Carlo Gavazzi):\u003c\/b\u003e DPC01DM69\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eComponent Type:\u003c\/b\u003e Multi-Function 3-Phase Voltage and Phase Monitoring Relay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eVoltage Range:\u003c\/b\u003e 380 to 690 VAC line-to-line (Wide range power supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eOutput Configuration:\u003c\/b\u003e 2 x SPDT (Single Pole Double Throw) output relays (8A \/ 250 VAC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMounting Type:\u003c\/b\u003e 35 mm DIN rail mounting enclosure (22.5 mm width)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parts4REM","offers":[{"title":"Default Title","offer_id":49852884910232,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_49b5677f-5ed7-499c-bd98-c0add5ba5130.jpg?v=1788967535"}],"url":"https:\/\/parts4rem.ca\/collections\/single-pole-relay.oembed","provider":"Parts4REM","version":"1.0","type":"link"}