{"product_id":"eaton-dilm150-xhi22-contacter-auxiliary","title":"Gemini said Eaton Moeller DILM150-XHI22 Auxiliary Block","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eEaton Moeller DILM150-XHI22\u003c\/b\u003e is a front-mounted auxiliary contact block from the \u003cb data-path-to-node=\"1\" data-index-in-node=\"84\"\u003exStart\u003c\/b\u003e series. In Canadian elevator maintenance, this specific block is the standard logic interface for high-amperage \u003cb data-path-to-node=\"1\" data-index-in-node=\"203\"\u003eMain Line\u003c\/b\u003e and \u003cb data-path-to-node=\"1\" data-index-in-node=\"217\"\u003eHydraulic Pump\u003c\/b\u003e contactors (specifically those between \u003cb data-path-to-node=\"1\" data-index-in-node=\"271\"\u003e80A and 170A\u003c\/b\u003e). It translates the mechanical state of the heavy power poles into the low-voltage feedback required by the elevator's CPU.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e DILM150-XHI22\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eMounting:\u003c\/b\u003e Front-mount (Center-pull snap-on)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eContact Configuration:\u003c\/b\u003e \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"23\"\u003e2 NO + 2 NC\u003c\/b\u003e (4 Poles total)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e DILM80 through DILM170 contactors (Large Frame)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eCurrent Rating (\u003cspan class=\"math-inline\" data-math=\"I_{th}\" data-index-in-node=\"16\"\u003e$I_{th}$\u003c\/span\u003e):\u003c\/b\u003e \u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"25\"\u003e16A\u003c\/b\u003e (Pilot duty \/ Control circuit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eTerminal Type:\u003c\/b\u003e Screw terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic (2 NO + 2 NC)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThis 4-pole configuration is designed to handle the multi-layered logic required by modern Canadian controllers:\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e2 NO (Normally Open):\u003c\/b\u003e Typically used for \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"41\"\u003eSeal-in\u003c\/b\u003e (holding) circuits and providing a \"Contactor Ready\" signal to the \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"116\"\u003eVFD\u003c\/b\u003e or \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"123\"\u003eBrake Controller\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2 NC (Normally Closed):\u003c\/b\u003e One is dedicated to \u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"44\"\u003eContactor Monitoring (B44 Code)\u003c\/b\u003e feedback. The second is frequently used for \u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"120\"\u003eElectrical Interlocking\u003c\/b\u003e (e.g., preventing the Delta contactor from pulling in while the Star contactor is made).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"8\"\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eBecause this block is part of the modular xStart system, it is frequently used alongside:\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eCompatible Contactor Frames\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eDILM80-11(120V60HZ):\u003c\/b\u003e 80A Main Line Contactor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eDILM150-11(120V60HZ):\u003c\/b\u003e 150A Large Hydraulic Pump Contactor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eAlternative Logic Blocks\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eDILM150-XHIR22:\u003c\/b\u003e Features \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"25\"\u003e\"R\" (Interlocked)\u003c\/b\u003e contacts—specifically designed for safety circuits to ensure no overlap between NO and NC states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eDILM1000-XHI11-SI:\u003c\/b\u003e Side-mounted version (1 NO + 1 NC) used when front-mount depth is restricted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eSurge Suppression\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eDILM150-XSPV240:\u003c\/b\u003e Varistor suppressor (110V-240V). Essential for protecting the controller's logic outputs from the significant inductive kickback of the larger DILM80-150 coils.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"17\"\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eField Maintenance \u0026amp; Canadian Code Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eB44 Safety Compliance:\u003c\/b\u003e These auxiliary contacts are certified as \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"65\"\u003eMirror Contacts\u003c\/b\u003e. Per Canadian code, they are mechanically linked to the main power poles. If a main contact welds, the NC monitoring contact is held open, preventing the elevator from resetting or attempting a new run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eInstallation Check:\u003c\/b\u003e When snapping the block onto the contactor, ensure the yellow carrier in the center of the contactor is properly aligned. If misaligned, the block will not cycle, leading to \"Safety String Open\" or \"Feedback Error\" faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eVibration Resistance:\u003c\/b\u003e These blocks are designed for high-cycle environments. However, in high-vibration machine rooms, verify that the screw terminals are torqued to \u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"166\"\u003e1.2 Nm\u003c\/b\u003e. Loose connections here are a common cause of \"flickering\" safety string inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,0\"\u003e\u003cb data-path-to-node=\"19,3,0\" data-index-in-node=\"0\"\u003eMaintenance:\u003c\/b\u003e Do not use contact cleaner or files on the internal silver points of this block. If the contact resistance exceeds 2 Ohms, replace the block to ensure the reliability of the monitoring circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48120295850136,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_6716dd4e-e35b-4360-87b5-ab7628cfcf70.jpg?v=1771953690","url":"https:\/\/parts4rem.ca\/products\/eaton-dilm150-xhi22-contacter-auxiliary","provider":"Parts4REM","version":"1.0","type":"link"}