{"product_id":"eaton-dilm40-xtce040d00b","title":"Eaton Moeller DILM40 Contactor","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eEaton Moeller DILM40\u003c\/b\u003e is a 3-pole IEC power contactor widely utilized in Canadian elevator systems, specifically for \u003cb data-path-to-node=\"1\" data-index-in-node=\"120\"\u003eHydraulic Pump Starters\u003c\/b\u003e and \u003cb data-path-to-node=\"1\" data-index-in-node=\"148\"\u003eTraction Hoist Motors\u003c\/b\u003e. As part of the Moeller \"xStart\" series, it is a \u003cb data-path-to-node=\"1\" data-index-in-node=\"219\"\u003eFrame 3\u003c\/b\u003e device, recognized for its twin-terminal design which allows for easier wiring of different cable cross-sections.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eFrame Size:\u003c\/b\u003e Frame 3 (55mm wide)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eCurrent Rating (AC-3):\u003c\/b\u003e \u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"23\"\u003e40A\u003c\/b\u003e (Approx. 25 HP at 460V \/ 30 HP at 575V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eCoil Voltage:\u003c\/b\u003e \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"14\"\u003e220V 50Hz \/ 240V 60Hz\u003c\/b\u003e (Common in older Canadian 240V control logic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eIntegrated Contacts:\u003c\/b\u003e \u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"21\"\u003eNone (0 NO \/ 0 NC)\u003c\/b\u003e — This is a base power unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eTerminal Type:\u003c\/b\u003e Screw terminals with \"Box\" clamps for secure high-amperage connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eAuxiliary Contact Options (DILM150-XHI)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eBecause the base DILM40 has no built-in logic contacts, you must add an auxiliary block to handle the elevator's safety and operational signals:\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eDILM150-XHI22:\u003c\/b\u003e \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"15\"\u003e2 NO + 2 NC.\u003c\/b\u003e The standard configuration for Canadian elevator controllers. Provides 1 NC for safety string monitoring, 1 NC for electrical interlocking, 1 NO for seal-in, and 1 NO for brake signaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eDILM150-XHI11:\u003c\/b\u003e \u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"15\"\u003e1 NO + 1 NC.\u003c\/b\u003e A compact option for basic run\/feedback logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eDILM1000-XHI11-SI:\u003c\/b\u003e \u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"19\"\u003e1 NO + 1 NC (Side-Mount).\u003c\/b\u003e Used in shallow cabinets or MRL applications to save depth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"8\"\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eThermal Overload Protection\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe DILM40 is typically paired with the \u003cb data-path-to-node=\"10\" data-index-in-node=\"40\"\u003eZB65\u003c\/b\u003e series of thermal overload relays, which plug directly into the bottom of the contactor:\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eZB65-40:\u003c\/b\u003e \u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"9\"\u003e24A to 40A\u003c\/b\u003e range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eZB65-57:\u003c\/b\u003e \u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"9\"\u003e40A to 57A\u003c\/b\u003e range (Often used if the motor FLA is exactly 40A to prevent nuisance tripping).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"12\"\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eField Maintenance \u0026amp; Canadian Code Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eVoltage Verification:\u003c\/b\u003e In many Canadian jurisdictions, 240V coils were standard in \"industrial-style\" controllers. Ensure the coil code matches your transformer output. If you apply 120V to this \u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"194\"\u003e240V coil\u003c\/b\u003e, the contactor will \"chatter,\" causing the main power poles to arc and eventually weld.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eMirror Contact Safety:\u003c\/b\u003e Eaton Moeller auxiliary contacts are \u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"60\"\u003emechanically linked (Mirror Contacts)\u003c\/b\u003e. Per Canadian B44 code, if a power pole welds, the NC auxiliary contact is guaranteed to stay open. This allows the CPU to detect the failure and prevent the car from moving.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eTwin-Terminal Design:\u003c\/b\u003e Frame 3 contactors feature two separate terminal chambers per pole. This is ideal for elevator controllers that use \"double-up\" wiring for high-current hydraulic pumps. Ensure both sides are torqued to \u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"224\"\u003e3.3 Nm\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eDust \u0026amp; Environmental Care:\u003c\/b\u003e Moeller contactors are robust, but in dusty machine rooms, the armature can become sluggish. If you hear a \"humming\" noise while the contactor is energized, the pole faces may need cleaning, or the coil may be nearing the end of its life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"15\"\u003e\n\u003ch3 data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003ePart Number Clarification\u003c\/b\u003e\u003c\/h3\u003e\n\u003cblockquote data-path-to-node=\"17\"\u003e\n\u003cp data-path-to-node=\"17,0\"\u003e\u003cb data-path-to-node=\"17,0\" data-index-in-node=\"0\"\u003eImportant:\u003c\/b\u003e If your unit is labeled \u003cb data-path-to-node=\"17,0\" data-index-in-node=\"35\"\u003eDILM40-22\u003c\/b\u003e, it is a factory-assembled version that includes the \u003cb data-path-to-node=\"17,0\" data-index-in-node=\"98\"\u003e2 NO + 2 NC\u003c\/b\u003e block already attached. If it is labeled only \u003cb data-path-to-node=\"17,0\" data-index-in-node=\"156\"\u003eDILM40\u003c\/b\u003e, it is the \"naked\" version.\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48120295162008,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_d971d5c8-60ff-4f31-8eeb-891ac590cdaa.jpg?v=1771954320","url":"https:\/\/parts4rem.ca\/products\/eaton-dilm40-xtce040d00b","provider":"Parts4REM","version":"1.0","type":"link"}