{"product_id":"eaton-dilm65-xtce065d00a-contacter","title":"Eaton Moeller DILM65 (XTCE065D00B) Contactor","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eEaton Moeller DILM65\u003c\/b\u003e (global part number) or \u003cb data-path-to-node=\"1\" data-index-in-node=\"49\"\u003eXTCE065D00B\u003c\/b\u003e (North American designation) is a 3-pole IEC contactor. In the Canadian elevator market, this \u003cb data-path-to-node=\"1\" data-index-in-node=\"155\"\u003eFrame 3\u003c\/b\u003e device is a \"heavy-hitter\" typically used for \u003cb data-path-to-node=\"1\" data-index-in-node=\"209\"\u003eLarge Hydraulic Pump Starters\u003c\/b\u003e and high-capacity \u003cb data-path-to-node=\"1\" data-index-in-node=\"257\"\u003eTraction Main Line\u003c\/b\u003e contactors.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe \u003cb data-path-to-node=\"2\" data-index-in-node=\"4\"\u003e\"B\"\u003c\/b\u003e suffix in the North American part number confirms a \u003cb data-path-to-node=\"2\" data-index-in-node=\"60\"\u003e120V AC (60Hz)\u003c\/b\u003e coil, which is the standard logic voltage for the majority of modern Canadian elevator controllers (MCE, GAL, etc.).\u003c\/p\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eFrame Size:\u003c\/b\u003e Frame 3 (55mm wide)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eCurrent Rating (AC-3):\u003c\/b\u003e \u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"23\"\u003e65A\u003c\/b\u003e (Approx. 40 HP at 460V \/ 50 HP at 575V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eCurrent Rating (AC-1):\u003c\/b\u003e \u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"23\"\u003e98A\u003c\/b\u003e (Resistive\/Non-inductive loads)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eCoil Voltage:\u003c\/b\u003e \u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"14\"\u003e120V AC, 60Hz\u003c\/b\u003e (Standard Canadian logic voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eIntegrated Contacts:\u003c\/b\u003e \u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"21\"\u003eNone (0 NO \/ 0 NC)\u003c\/b\u003e — This is a base unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003eTerminals:\u003c\/b\u003e Twin-chamber box terminals for secure high-current landing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"5\"\u003e\n\u003ch3 data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eAuxiliary Contact Blocks (DILM150-XHI)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eSince the \u003cb data-path-to-node=\"7\" data-index-in-node=\"10\"\u003eXTCE065D00B\u003c\/b\u003e has no integrated auxiliaries, you must snap on an external block to handle the safety string and brake signals:\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eDILM150-XHI22:\u003c\/b\u003e \u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"15\"\u003e2 NO + 2 NC.\u003c\/b\u003e The industry-standard \"4-pole\" setup. Provides 1 NC for contactor state monitoring (B44 safety), 1 NC for electrical interlocking, 1 NO for seal-in, and 1 NO for brake control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eDILM1000-XHI11-SI:\u003c\/b\u003e \u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"19\"\u003e1 NO + 1 NC (Side-Mount).\u003c\/b\u003e Ideal for shallow MRL (Machine Room-Less) cabinets where front-mounted blocks would prevent the door from closing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"9\"\u003e\n\u003ch3 data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eThermal Overload Protection\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"11\"\u003eFor a 65A application, the \u003cb data-path-to-node=\"11\" data-index-in-node=\"27\"\u003eZB65\u003c\/b\u003e series overloads plug directly into the bottom of this contactor:\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eZB65-65:\u003c\/b\u003e \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"9\"\u003e50.0A to 65.0A\u003c\/b\u003e (The standard match for this contactor).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eZB65-75:\u003c\/b\u003e 65.0A to 75.0A (Used if the pump motor FLA is right at the 65A threshold).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003ch3 data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eField Maintenance \u0026amp; Canadian Code Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eB44 Safety Compliance:\u003c\/b\u003e Per Canadian code, you \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"46\"\u003emust\u003c\/b\u003e use an NC contact on this unit for \"Contactor Monitoring.\" Moeller's \u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"120\"\u003eMirror Contact\u003c\/b\u003e design ensures that if a power pole welds, the NC auxiliary contact remains open, allowing the CPU to detect the hazard and prevent a restart.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eTorque Warning:\u003c\/b\u003e For a 65A load, terminal integrity is critical. Ensure power leads are torqued to \u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"98\"\u003e3.3 Nm (30 lb-in)\u003c\/b\u003e. High-vibration environments can loosen these terminals, leading to \"single-phasing,\" which can burn out an expensive hydraulic pump motor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eCoil Voltage Check:\u003c\/b\u003e While \"B\" (120V) is standard, always verify against the controller transformer. If you install this 120V unit in an older 240V system (which requires the \"A\" suffix), the coil will fail instantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eThe \"Hum\" Test:\u003c\/b\u003e If the contactor produces a loud buzzing or humming noise while energized, it usually indicates dust on the pole faces or a failing coil. In a quiet apartment building, this vibration can often be heard inside the cab.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":48120294899864,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_f7dc6e74-629d-4f17-8a1f-354909d542ca.jpg?v=1771954422","url":"https:\/\/parts4rem.ca\/products\/eaton-dilm65-xtce065d00a-contacter","provider":"Parts4REM","version":"1.0","type":"link"}