{"product_id":"mce-ice-mor","title":"MCE-ICE-MOR","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eMCE-ICE-MOR\u003c\/b\u003e is a specialized modernization engineering package designed by Motion Control Engineering (MCE). It serves as an integrated controller solution specifically engineered to upgrade and replace legacy \u003cb data-path-to-node=\"1\" data-index-in-node=\"214\"\u003eOtis ICE (Integrated Control Equipment)\u003c\/b\u003e elevator systems, while retaining the existing \u003cb data-path-to-node=\"1\" data-index-in-node=\"301\"\u003eOtis MOR (Machine Room)\u003c\/b\u003e gearless traction machines.\u003c\/p\u003e\n\u003cul data-path-to-node=\"2\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,0,0\"\u003e\u003cb data-path-to-node=\"2,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e Motion Control Engineering (MCE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,1,0\"\u003e\u003cb data-path-to-node=\"2,1,0\" data-index-in-node=\"0\"\u003eTarget Application:\u003c\/b\u003e High-speed, high-rise gearless traction elevator modernization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,2,0\"\u003e\u003cb data-path-to-node=\"2,2,0\" data-index-in-node=\"0\"\u003eControl Architecture:\u003c\/b\u003e Motion 4000 or iControl processor integration (depending on specific building velocity and dispatching requirements).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"2,3,0\"\u003e\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eDrive Compatibility:\u003c\/b\u003e High-performance AC or DC digital drives configured to match the exact voltage and amperage requirements of the legacy Otis MOR machine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"4\"\u003eElevator Logic\u003c\/h2\u003e\n\u003cp data-path-to-node=\"5\"\u003eThis modernization package replaces the obsolete Otis ICE relay or early solid-state logic with a modern, micro-processor-based control system.\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eDispatching \u0026amp; Performance:\u003c\/b\u003e Implements advanced destination dispatching capabilities or intelligent group supervisor logic to drastically reduce wait times and improve traffic flow compared to the original legacy logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eMotion Profile:\u003c\/b\u003e Features absolute position systems (using a steel tape or optical encoder system in the hoistway) to provide precise floor leveling accuracy within 1\/4 inch (6 mm) and smooth acceleration\/deceleration curves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eSafety Integration:\u003c\/b\u003e Fully integrates software-based monitoring of all critical safety circuits, including independent door lock monitoring, unintended car movement protection, and ascending car overspeed detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"8\"\u003eAccessories\u003c\/h2\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe MCE-ICE-MOR package bridges the gap between old mechanical equipment and modern digital infrastructure by utilizing custom-engineered interface accessories:\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eIsolation Transformers \u0026amp; Reactors:\u003c\/b\u003e Line reactors and isolation transformers specifically matched to the building's electrical supply to minimize line harmonics and acoustic noise generated by the new drive system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eUniversal Wiring Harnesses:\u003c\/b\u003e Pre-engineered wiring looms and terminal block layouts tailored to interface seamlessly with existing hoistway junction boxes and car top stations, minimizing field installation time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eFixtures \u0026amp; Displays:\u003c\/b\u003e Serial communication interfaces that allow plug-and-play installation of modern hall lanterns, position indicators, and car operating panels (COP).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"12\"\u003eMaintenance \/ Code Details\u003c\/h2\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eCode Compliance:\u003c\/b\u003e Fully compliant with \u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"38\"\u003eASME A17.1 \/ CSA B44\u003c\/b\u003e (Handbook on Elevator and Escalator safety codes for Canada). This includes mandatory provisions for Firefighters' Service (Phase I and II), emergency power sequencing, and two-way visual\/audio communication systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eDiagnostics \u0026amp; Troubleshooting:\u003c\/b\u003e Features an onboard diagnostic display and compatibility with MCE’s computer-based monitoring software. This allows maintenance technicians to view real-time fault codes, system status logs, and input\/output states without requiring proprietary tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eSolid-State Reliability:\u003c\/b\u003e By eliminating legacy mechanical relays and aging carbon-pile regulators, the system drastically lowers routine maintenance requirements, reduces machine room heat output, and improves overall building energy efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49249698513048,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_1295750f-57fc-44d6-8ff7-a8244c396cd3.jpg?v=1781560770","url":"https:\/\/parts4rem.ca\/products\/mce-ice-mor","provider":"Parts4REM","version":"1.0","type":"link"}