{"product_id":"sc-baser-d","title":"MCE SC-BASER-D Interface Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSC-BASER-D\u003c\/b\u003e is a specialized high-speed serial interface and logic distribution board manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"105\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e. This board is specifically designed for the \u003cb data-path-to-node=\"1\" data-index-in-node=\"183\"\u003eMotion 4000\u003c\/b\u003e and \u003cb data-path-to-node=\"1\" data-index-in-node=\"199\"\u003eiControl\u003c\/b\u003e systems to facilitate communication between the main controller and auxiliary hardware.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e: Serial Network Interface \/ Logic PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e: Motion Control Engineering (MCE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eSystem Compatibility\u003c\/b\u003e: Motion 4000 and iControl Series controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCommunication Protocol\u003c\/b\u003e: High-speed Universal Serial Network (USN).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eI\/O Capacity\u003c\/b\u003e: Supports multiple auxiliary inputs and outputs via pluggable terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eDistributed Serial Hub\u003c\/b\u003e: Serves as a primary node on the Universal Serial Network, allowing the main processor to communicate with various car and hall stations through a simplified serial bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSignal Translation\u003c\/b\u003e: Acts as the interface point for auxiliary signals, routing high-voltage field inputs to the low-voltage logic processing of the main controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eEmergency Logic Interface\u003c\/b\u003e: Frequently used to manage inputs for Fire Phase I\/II, medical emergency operation, and earthquake sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eOn-board Diagnostic Monitoring\u003c\/b\u003e: Built-in circuitry allows the board to report its own status back to the main CPU for real-time fault monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eShielded Serial Cables\u003c\/b\u003e: High-quality twisted-pair cabling required to prevent electromagnetic interference on the data bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003ePluggable Terminal Blocks\u003c\/b\u003e: Removable screw-terminal connectors that allow for quick field replacement without individual rewiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eStandoff Mounting Kits\u003c\/b\u003e: Insulated mounting hardware used to secure the board within the control cabinet while preventing electrical shorts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance\u003c\/b\u003e: To maintain \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"38\"\u003eCSA B44.1\/ASME A17.5\u003c\/b\u003e equipment certification, replacement boards must match the original revision number exactly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eDiagnostic LEDs\u003c\/b\u003e: On-board indicators provide status for power, transmit (TX), and receive (RX); a steady \"Heartbeat\" LED confirms the board's internal processor is active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eTermination Jumper Settings\u003c\/b\u003e: The board must be correctly jumpered (using the \"Term\" jumper) if it is located at the physical end of the serial communication line to maintain bus impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eEnvironmental Requirements\u003c\/b\u003e: Rated for operation in machine rooms between 0°C and 40°C with protection against condensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49103098642584,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_b28ed87c-7d98-4df6-95eb-47acb49d9886.jpg?v=1778707645","url":"https:\/\/parts4rem.ca\/products\/sc-baser-d","provider":"Parts4REM","version":"1.0","type":"link"}