{"product_id":"sc-basr-t","title":"MCE SC-BASR-T Interface Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSC-BASR-T\u003c\/b\u003e is a high-speed serial interface and logic board manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"79\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e. It serves as a primary hub for distributed I\/O communication between the main processor and field devices within \u003cb data-path-to-node=\"1\" data-index-in-node=\"226\"\u003eMotion 4000\u003c\/b\u003e and legacy \u003cb data-path-to-node=\"1\" data-index-in-node=\"249\"\u003eVFMC\u003c\/b\u003e controller series.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e: Serial Network Interface \/ Logic PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e: Motion Control Engineering (MCE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eSystem Compatibility\u003c\/b\u003e: Motion 4000, iControl, and VFMC Series controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCommunication Protocol\u003c\/b\u003e: High-speed Universal Serial Network (USN).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eI\/O Capacity\u003c\/b\u003e: Supports multiple auxiliary inputs and outputs via pluggable terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eSerial Communication Hub\u003c\/b\u003e: Acts as a central node for the Universal Serial Network, allowing the main CPU to communicate with remote car and hall stations through a simplified wiring bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eSafety \u0026amp; Fire Logic Interface\u003c\/b\u003e: Frequently routes critical auxiliary signals such as Fire Phase I\/II recall, earthquake operation inputs, and emergency power status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eProgrammable Bypasses\u003c\/b\u003e: Features on-board dip switches or jumpers used to temporarily override specific faults during installation or maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eSignal Isolation\u003c\/b\u003e: Provides electrical isolation between high-voltage field signals and the low-voltage logic traces of the main controller processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eShielded Serial Cables\u003c\/b\u003e: Specific twisted-pair cabling required to maintain data integrity across the serial network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003ePluggable Terminal Blocks\u003c\/b\u003e: Removable screw-terminal connectors that allow for quick board replacement without rewiring individual field leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eStandoff Mounting Kits\u003c\/b\u003e: Insulated plastic or metal standoffs used to secure the board within the NEMA-rated controller cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance\u003c\/b\u003e: To maintain \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"38\"\u003eCSA B44.1\/ASME A17.5\u003c\/b\u003e equipment certification, replacement boards must match the original revision number exactly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eDiagnostic LEDs\u003c\/b\u003e: On-board indicators provide real-time status of power and data activity; a flickering \"Heartbeat\" LED typically indicates healthy communication with the main CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eTermination Jumper Settings\u003c\/b\u003e: The board must be correctly jumpered if it is at the end of the serial communication line to ensure proper bus impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eEnvironmental Requirements\u003c\/b\u003e: Rated for operation in machine rooms between \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"73\"\u003e0°C and 40°C\u003c\/b\u003e with protection against condensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49103116632216,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_b28ed87c-7d98-4df6-95eb-47acb49d9886.jpg?v=1778707645","url":"https:\/\/parts4rem.ca\/products\/sc-basr-t","provider":"Parts4REM","version":"1.0","type":"link"}