{"product_id":"sprecher-schuh-ca7-12-10-120","title":"Sprecher + Schuh CA7-12-10-120 Contactor","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eSprecher + Schuh CA7-12-10-120\u003c\/b\u003e is a compact, high-performance 3-pole contactor from the \u003cb data-path-to-node=\"1\" data-index-in-node=\"92\"\u003eCA7 series\u003c\/b\u003e. In the Canadian elevator industry, this unit is a common sight in \u003cb data-path-to-node=\"1\" data-index-in-node=\"170\"\u003eDoor Operator\u003c\/b\u003e circuits, \u003cb data-path-to-node=\"1\" data-index-in-node=\"194\"\u003eBrake Control\u003c\/b\u003e logic, and smaller \u003cb data-path-to-node=\"1\" data-index-in-node=\"227\"\u003eHydraulic\/Traction\u003c\/b\u003e auxiliary systems. The \u003cb data-path-to-node=\"1\" data-index-in-node=\"269\"\u003e\"-120\"\u003c\/b\u003e suffix specifically denotes the standard Canadian \u003cb data-path-to-node=\"1\" data-index-in-node=\"326\"\u003e120V AC, 60Hz\u003c\/b\u003e coil.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e CA7-12-10-120\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eAmperage (AC-3):\u003c\/b\u003e \u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"17\"\u003e12A\u003c\/b\u003e (Approx. 10 HP @ 575V \/ 7.5 HP @ 460V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eCoil Voltage:\u003c\/b\u003e \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"14\"\u003e120V AC, 60Hz\u003c\/b\u003e (Standard Canadian Logic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eIntegrated Contacts:\u003c\/b\u003e \u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"21\"\u003e1 NO\u003c\/b\u003e (Normally Open)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eFrame Size:\u003c\/b\u003e 45mm width (Standard small frame)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eTerminal Type:\u003c\/b\u003e Screw terminals (Pozi-drive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic (Integrated 1 NO)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThis specific model comes with a single integrated \u003cb data-path-to-node=\"6\" data-index-in-node=\"51\"\u003eNormally Open\u003c\/b\u003e contact:\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1 NO (Normally Open):\u003c\/b\u003e Typically used as a \u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"42\"\u003eSeal-in\u003c\/b\u003e contact to keep the coil energized after a momentary \"Run\" command, or to provide an \"Operational\" signal to the controller's logic board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eLogic Gap:\u003c\/b\u003e Because this model (the \"-10\") lacks an integrated NC contact, a \u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"76\"\u003eNormally Closed auxiliary block\u003c\/b\u003e must be added to satisfy \u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"133\"\u003eB44 Contactor Monitoring\u003c\/b\u003e requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"8\"\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe CA7 series is highly modular, allowing for various logic and protection upgrades:\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eAuxiliary Contact Blocks\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCS7-PV-11:\u003c\/b\u003e Front-mounted (1 NO + 1 NC) — \u003ci data-path-to-node=\"12,0,0\" data-index-in-node=\"41\"\u003eMost common for adding B44 feedback.\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eCS7-PV-22:\u003c\/b\u003e Front-mounted (2 NO + 2 NC) — For complex safety string interlocking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eCS7-L-11:\u003c\/b\u003e Side-mounted (1 NO + 1 NC) — Essential for slim \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"58\"\u003eMRL\u003c\/b\u003e or door operator boxes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eElectronic Overload Relays (Direct Mount)\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eCEP7-1EEAB:\u003c\/b\u003e 0.2A to 1.0A (Typical for small door motors).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eCEP7-1EEED:\u003c\/b\u003e 3.2A to 16A (Standard for hoist-related auxiliary loads).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eSurge Suppressors\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eRC7-120:\u003c\/b\u003e RC Link (110-280V AC) — Plugs into the top of the contactor to snub inductive spikes and prevent CPU \"glitches.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"17\"\u003e\n\u003ch3 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eField Maintenance \u0026amp; Canadian Code Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eB44 Safety Compliance:\u003c\/b\u003e When an auxiliary block is added, these contacts function as \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"84\"\u003eMechanically Linked \/ Mirror Contacts\u003c\/b\u003e. Per Canadian code, if a power pole welds, the NC auxiliary is held open, preventing the CPU from clearing the safety string for the next run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eTerminal Torque:\u003c\/b\u003e Screws should be torqued to \u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"45\"\u003e1.2 Nm (10.6 lb-in)\u003c\/b\u003e. Over-torquing can strip the plastic housing, while under-torquing leads to arcing and \"ghost\" faults in the safety circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eCompact Footprint:\u003c\/b\u003e The CA7 is one of the narrowest 12A contactors available. If you are replacing a bulkier legacy brand in a crowded controller, this unit will often fit with room to spare on the DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,0\"\u003e\u003cb data-path-to-node=\"19,3,0\" data-index-in-node=\"0\"\u003eStandardization:\u003c\/b\u003e The CA7 series shares many parts with Allen-Bradley 100-C components, making it easier to find replacement auxiliary blocks in a pinch during service calls in remote areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":47739791081624,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_8bdce67e-6c14-44be-8f90-ad6195236769.jpg?v=1771962990","url":"https:\/\/parts4rem.ca\/products\/sprecher-schuh-ca7-12-10-120","provider":"Parts4REM","version":"1.0","type":"link"}