{"product_id":"tlsc-4-sw-mod-g2s","title":"MCE TLSC-4-SW-MOD-G2S","description":"\u003ch2 data-path-to-node=\"0\"\u003eCore Specifications\u003c\/h2\u003e\n\u003cul data-path-to-node=\"1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,0,0\"\u003e\u003cb data-path-to-node=\"1,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e MCE (Motion Control Engineering)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,1,0\"\u003e\u003cb data-path-to-node=\"1,1,0\" data-index-in-node=\"0\"\u003eModel Number:\u003c\/b\u003e TLSC-4-SW-MOD-G2S\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,2,0\"\u003e\u003cb data-path-to-node=\"1,2,0\" data-index-in-node=\"0\"\u003eRevision:\u003c\/b\u003e REV. 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,3,0\"\u003e\u003cb data-path-to-node=\"1,3,0\" data-index-in-node=\"0\"\u003eComponent Type:\u003c\/b\u003e Top of Car Inspection \/ Station Control Module Panel Faceplate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,4,0\"\u003e\u003cb data-path-to-node=\"1,4,0\" data-index-in-node=\"0\"\u003eMaterial:\u003c\/b\u003e Heavy-duty, textured impact-resistant thermoplastic polymer or powder-coated composite.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"1,5,0\"\u003e\u003cb data-path-to-node=\"1,5,0\" data-index-in-node=\"0\"\u003eMounting:\u003c\/b\u003e Pre-drilled lower structural mounting holes for secure fastening to the inspection box housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"3\"\u003eElevator Logic\u003c\/h2\u003e\n\u003cp data-path-to-node=\"4\"\u003eThis module panel interfaces directly with the MCE elevator controller logic to govern safe, manual operation during maintenance, inspection, or installation phases.\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eInspection Mode Override:\u003c\/b\u003e When the inspection switch is toggled, it cuts normal automatic operation logic, transferring complete directional control exclusively to the local top-of-car station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eSafety Circuit Integration:\u003c\/b\u003e Operating logic complies with stringent fail-safe electrical requirements. Dead-man functionality requires simultaneous actuation of a directional input and an enabling\/safety button to complete the logic circuit and initiate car movement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eSystem Diagnostics:\u003c\/b\u003e The revision 3 architectural layout integrates seamlessly with MCE Generation 2 serial (G2S) link networks or modular configurations, sending clean digital or discrete feedback signals back to the main controller regarding the status of the inspection switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"7\"\u003eAccessories\u003c\/h2\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eIntegrated Switches:\u003c\/b\u003e Designed to house critical toggle or push-button components, including:\u003c\/p\u003e\n\u003cul data-path-to-node=\"8,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,1,0,0\"\u003e\u003cb data-path-to-node=\"8,0,1,0,0\" data-index-in-node=\"0\"\u003eInspection\/Normal Selector Switch:\u003c\/b\u003e Transfers control between automatic operation and manual inspection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,1,1,0\"\u003e\u003cb data-path-to-node=\"8,0,1,1,0\" data-index-in-node=\"0\"\u003eDirectional Switches:\u003c\/b\u003e Up and Down manual run controls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,1,2,0\"\u003e\u003cb data-path-to-node=\"8,0,1,2,0\" data-index-in-node=\"0\"\u003eEmergency Stop Button:\u003c\/b\u003e High-visibility, positive-break red mushroom switch (typically mounted adjacent or integrated).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eMarkings \u0026amp; Labels:\u003c\/b\u003e High-contrast, durable text windows indicating switch states (e.g., ON, OFF).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"10\"\u003eMaintenance and Code Details\u003c\/h2\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance:\u003c\/b\u003e This component is designed to be utilized in inspection stations meeting the strict requirements of \u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"126\"\u003eASME A17.1\/CSA B44\u003c\/b\u003e (Safety Code for Elevators and Escalators). It fulfills the criteria for top-of-car operating devices regarding accessibility, clear identification, and separation of control functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eMaintenance Protocol:\u003c\/b\u003e During routine maintenance visits, the faceplate integrity should be inspected for cracks or warping that could compromise the underlying electrical contacts. Ensure all text labels remain legible and free from grease or debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eEnvironmental Rating:\u003c\/b\u003e Built to withstand the harsh, dusty environments typically found in elevator hoistways and overhead machine spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49229204324504,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_c1250ecd-b811-4647-a570-543dacde420f.jpg?v=1781202827","url":"https:\/\/parts4rem.ca\/products\/tlsc-4-sw-mod-g2s","provider":"Parts4REM","version":"1.0","type":"link"}