{"product_id":"untitled-dec9_13-17","title":"Potter \u0026 Brumfield K10P-11D15-24 Relay","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eK10P-11D15-24\u003c\/b\u003e (manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"35\"\u003eTE Connectivity\u003c\/b\u003e) is a compact, high-performance \"Miniature\" general-purpose relay. It is essentially the smaller, space-saving version of the standard KUP series. In elevator systems, it is frequently used on high-density controller boards and car-top stations where cabinet space is limited but high-current switching (up to 15A) is still required.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e TE Connectivity \/ Potter \u0026amp; Brumfield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e K10P-11D15-24\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eNumber of Poles:\u003c\/b\u003e \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"17\"\u003e2-Pole (DPDT \/ 2 Form C)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCoil Voltage:\u003c\/b\u003e 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eContact Rating:\u003c\/b\u003e 15A @ 120V AC \/ 10A @ 240V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eBase Type:\u003c\/b\u003e 8-Pin Square Plug-in (Fine blade\/solder terminals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,6,0\"\u003e\u003cb data-path-to-node=\"3,6,0\" data-index-in-node=\"0\"\u003eConstruction:\u003c\/b\u003e Clear polycarbonate \"Ice Cube\" dust cover\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003e2-Pole DPDT Switching:\u003c\/b\u003e The \u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"27\"\u003edual-pole\u003c\/b\u003e configuration allows the relay to switch two separate circuits simultaneously. In elevator logic, this is often used to switch a 110V AC load (like a signal chime) on one pole while providing a 24V DC \"Position Acknowledged\" feedback signal to the CPU on the second pole.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eHigh-Density Output:\u003c\/b\u003e Because of its smaller footprint compared to the KUP series, it is used as a pilot relay to drive larger contactors or as an interface for multi-speed door operators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eBrake Holding:\u003c\/b\u003e Provides the logic-level signal to the brake controller to drop the brake to a \"holding\" voltage once the car has reached full speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eSignal Isolation:\u003c\/b\u003e Protects sensitive microprocessor outputs from 24V DC field-induced transients from hall calls or limit switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003e27E891 Socket:\u003c\/b\u003e The standard 8-pin miniature square socket used for DIN-rail or screw mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003e20C217 Hold-Down Spring:\u003c\/b\u003e A metal wire clip used to lock the relay into the socket, critical for preventing \"vibration-out\" on car-top stations or vibrating controller cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eFlyback Diode:\u003c\/b\u003e Essential across the 24V DC coil (Terminals 7 \u0026amp; 8) to suppress inductive \"kick\" and protect the controller's transistor drivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eLED Indicator Module:\u003c\/b\u003e Optional plug-in modules for the socket to provide visual confirmation of coil energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eB44 Safety Limitations:\u003c\/b\u003e Under \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"30\"\u003eCanadian Elevator Code (B44)\u003c\/b\u003e, this is \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"68\"\u003enot\u003c\/b\u003e a force-guided safety relay. It must \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"109\"\u003enot\u003c\/b\u003e be used for primary safety-critical monitoring (such as door interlock verification) where a welded contact could cause a hazardous condition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003e15A Inrush Handling:\u003c\/b\u003e The K10P is rated for higher inrush than many standard miniature relays. However, switching inductive loads (coils\/motors) will eventually cause carbon buildup. If the relay \"clicks\" but the circuit fails, check for high resistance across the DPDT blades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eCoil Resistance:\u003c\/b\u003e The 24V DC coil has a nominal resistance of approximately \u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"75\"\u003e\u003cspan class=\"math-inline\" data-math=\"480 \\Omega\" data-index-in-node=\"75\"\u003e$480 \\Omega$\u003c\/span\u003e\u003c\/b\u003e. An \"Open\" reading indicates a blown coil, often caused by a failed surge suppressor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eMiniature vs. Standard:\u003c\/b\u003e Ensure the \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"35\"\u003eK10P\u003c\/b\u003e (Miniature) is not confused with the \u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"77\"\u003eKUP\u003c\/b\u003e (Standard). They use different sockets and have different terminal spacing; forcing a K10P into a KUP socket will damage the pins and the base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":47580460646552,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_1b030f81-d9f3-43bb-af12-f5706fe36ce7.jpg?v=1772734440","url":"https:\/\/parts4rem.ca\/products\/untitled-dec9_13-17","provider":"Parts4REM","version":"1.0","type":"link"}