{"product_id":"untitled-may13_10-02","title":"MCE HC-CTL-T Control Board","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eHC-CTL-T\u003c\/b\u003e is the \u003cb data-path-to-node=\"1\" data-index-in-node=\"20\"\u003eMain Traction Control Board\u003c\/b\u003e manufactured by \u003cb data-path-to-node=\"1\" data-index-in-node=\"64\"\u003eMotion Control Engineering (MCE)\u003c\/b\u003e. Unlike the hydraulic version, the \u003cb data-path-to-node=\"1\" data-index-in-node=\"132\"\u003e-T\u003c\/b\u003e suffix designates this board for \u003cb data-path-to-node=\"1\" data-index-in-node=\"168\"\u003eTraction\u003c\/b\u003e systems, where it manages the complex timing and feedback loops required for cable-driven elevators.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCore Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e: Main Logic \/ Processor PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e: Motion Control Engineering (MCE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eSystem Compatibility\u003c\/b\u003e: Primarily used in \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"40\"\u003eMCE HMC-1000-T\u003c\/b\u003e and \u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"59\"\u003eVFMC\u003c\/b\u003e (Variable Frequency Motion Control) traction systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eApplication\u003c\/b\u003e: Geared and gearless traction applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eI\/O Interface\u003c\/b\u003e: High-density connectors for interface with the drive, encoder feedback, and hoistway positioning systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"4\"\u003e\n\u003ch3 data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eElevator Logic\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMotion Profile Generation\u003c\/b\u003e: Calculates the S-curve acceleration and deceleration patterns specifically for traction motors to ensure smooth starts and stops without \"jerking.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eDrive Interface\u003c\/b\u003e: Communicates directly with the AC or DC drive to command speed and torque while monitoring the drive's \"Ready\" and \"Fault\" status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eEncoder Processing\u003c\/b\u003e: Processes high-speed pulses from the motor encoder to track car position and speed with millimeter precision, which is critical for floor leveling in traction systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eBrake Control Logic\u003c\/b\u003e: Manages the precise timing of the mechanical brake release and set sequences, ensuring the motor is producing enough torque to hold the load before the brake lifts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"7\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eAccessories\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eEncoder Cables\u003c\/b\u003e: Shielded, low-capacitance cables required to transmit pulse data from the motor to the board without signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eCommunication Bridge\u003c\/b\u003e: May be paired with a serial interface board (like the SC-BASR) to distribute I\/O to the car and hall stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003ePluggable Terminal Blocks\u003c\/b\u003e: Standard MCE-style green or black removable connectors for field wiring and easy board replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eMaintenance \u0026amp; Code\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eCanadian Code Compliance\u003c\/b\u003e: Replacement boards must match the original revision and software version to remain compliant with \u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"124\"\u003eCSA B44\u003c\/b\u003e standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eRevision Matching\u003c\/b\u003e: In traction systems, the board revision is critical; using an incompatible revision can cause \"roll-back\" or unintended motion due to differences in how the drive interface is handled.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eDiagnostics\u003c\/b\u003e: Use the onboard 7-segment display or LED array to monitor for traction-specific faults, such as \"Encoder Loss\" or \"Drive Fault.\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eESD Protection\u003c\/b\u003e: As with all MCE logic boards, the high-density microprocessors are extremely sensitive to static; always use grounded protection when handling the board during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"R.A.M. Parts","offers":[{"title":"Default Title","offer_id":49103012298904,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/4369\/5000\/files\/rn-image_picker_lib_temp_798e0635-730d-4c94-a140-ac41714ff58f.jpg?v=1778708063","url":"https:\/\/parts4rem.ca\/products\/untitled-may13_10-02","provider":"Parts4REM","version":"1.0","type":"link"}